CARE AND CLEANING 

Clean your air conditioner to keep it looking new 
and to minimize dust build up. 

 

Air Filter Cleaning 

The air filter should be checked at least once 
every month to see if it needs cleaning. Trapped 
particles and dust can build up in the filter and 
may decrease airflow as well as cause the    
cooling coils to accumulate frost. To clean the air 
filter: 
 
1.  Remove the filter by pulling down on the in-

dents of the filter door on the front of the unit. 
(See FIG. 

5

2. 

Wash the filter using liquid dish soap and 
warm water. Rinse the filter thoroughly. Gen-
tly shake the filter to remove excess water. 

 

3. 

Let the filter dry completely before placing it 
into the air conditioner.

 

4. 

If you do not wish to wash the filter, you may 
vacuum the filter to remove the dust and 
other particles.

 

 
 
 
 
 
 
 
 
 
 
 

Wear and Tear 

To minimize wear and tear on the air  condi-
tioner, always wait at least 3 minutes before 
changing modes. This will help prevent the   
compressor from overheating and the circuit 
breaker from tripping. 

Cabinet Cleaning 

To clean the air conditioner cabinet:  

• 

Unplug the air conditioner to prevent shock or 
a fire hazard. The cabinet and front panel of 
the air conditioner may be dusted with an oil-
free cloth or washed with a cloth dampened in 
a solution of warm water and mild liquid soap. 
Rinse thoroughly with a damp cloth and wipe 
dry. 

• 

Never use harsh cleaners, wax or polish on 
the cabinet front. 

• 

Be sure to wring excess water from the cloth 
before wiping around the controls. Excess 
water in or around the controls may cause 
damage to the air conditioner. 

 

Winter Storage

 

To store the air conditioner when it is not in use 
for an extended period of time, remove it care-
fully from the window according to the installation 
instructions and cover it with plastic or place it in 
the original box

.

 

 

FIG. 

5

 

 1

2

Indents

 

Summary of Contents for WM1-05M-01

Page 1: ...Model WM1 05M 01 Window Air Conditioner Operating Instructions 54 000 BTU...

Page 2: ...owner s manual carefully Store this manual in a safe place for future reference Your safety and the safety of others is very important to us Please pay attention to all safety messages outlined in thi...

Page 3: ...nd or to any exposed metal The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test 1 Plug power cord into wall outlet The LED light will turn on 2 Pre...

Page 4: ...st Window Air Conditioner 1 Top Mounting Rail 1 Insert Strip 1 Short Screw 8 Curtain 2 Sash Lock 2 Foam Seal 1 Long Screw for Window Locking Bracket Curtains 12 Curtain Lock 2 Owner s Manual 1 Weather...

Page 5: ...ay Product Dimensions W x H x D 18 625 x 12 625 x 15 5 Package Dimensions W x H x D 23 x 15 x 18 625 23 x 18 625 x 15 Net Gross Weight Lbs 46 55 46 55 Refrigerant Type R 410A R 410A Plug Type NEMA 5 1...

Page 6: ...ED INDEPENDENT TEST TO THE INFORMA TION AND THE SPECIFICATIONS PRESENTED HEREWITHIN 5 Power supply cord with 3 prong grounding plug and current detection device WARNING Avoid fire hazard or electronic...

Page 7: ...imately 1 2 higher than the storm window frame This will allow the air conditioner to tilt enough for proper drainage See FIG 2 Prior to Installing the Air Conditioner 1 Check for anything that could...

Page 8: ...utilization and drainage If you are not using the side panels the rear pitch must still be maintained 1 Attach the top rail onto the top of the outer case using four Short Screws 7 m o u n t i n g r...

Page 9: ...en installed Placing the Unit Inside a Normal Window 2 Once the air conditioner is placed extend the left and right curtains to the width of the window 3 Place the curtain lock between the curtain ext...

Page 10: ...sash seal from between windows and unscrew sash lock 3 Remove the screws installed through the frame and frame lock 4 Close slide the side panels into frame 5 Keeping a firm grip on air conditioner r...

Page 11: ...ter clockwise to select the lower cool settings Turn the MODE selector to OFF to turn off the unit Fan Mode Turn the MODE selector counter clockwise to select HIGH FAN MED FAN or LOW FAN Turn the MODE...

Page 12: ...ior to power loss Timer will be cancelled when power is lost or interrupted You may need to set a new time if desired Air Direction Use the lever on the front air vents to adjust the airflow direction...

Page 13: ...o minimize wear and tear on the air condi tioner always wait at least 3 minutes before changing modes This will help prevent the compressor from overheating and the circuit breaker from tripping Cabin...

Page 14: ...ngaged discontinue use of the air conditioner and contact a qualified service technician TROUBLESHOOTING The Air Conditioner does not cool as it should Airflow is restricted The temperature control ma...

Page 15: ...is not correctly tilted outside For proper water drainage make sure the air conditioner is slightly tilted downward from the front of the unit to the rear Water collects in the base pan Moisture remo...

Page 16: ...rmal wear and tear Warranty service must be performed by a qualified HVAC contractor Soleus Home Comfort maintains a centralized service network to provide parts and assist in resolving service proble...

Reviews: