background image

14 

 

Problem 

Possible Causes 

Solutions 

Dehumidifier does not 
start. 

The dehumidifier is un-
plugged. 

Make sure the dehumidifier’s plug is pushed 
completely into the outlet. 

The fuse is blown / cir-
cuit breaker is tripped. 

Check the house fuse / circuit breaker box and 
replace fuse or reset breaker. 

Dehumidifier has 
reached the user set 
humidity level or the 
bucket is full. 

The dehumidifier automatically turns off when 
either condition occurs. Change to a lower 
setting or empty the water bucket and replace 
properly. 

Bucket is not in the prop-
er position. 

The bucket must be in place and securely 
seated for the dehumidifier to operate. 

Power Failure. 

There is a protective time delay (up to 3 min.) 
to prevent tripping of the compressor overload. 
For this reason, the unit may not start normal 
dehumidification for 3 min. after it is powered 
back on. 

Dehumidifier is not 
operating as  
Intended. 

Not enough time allowed 
for unit to remove mois-
ture. 

When first installed, allow at least 24 hours to 
achieve the desired humidity level. 

 

Airflow is restricted. 

Make sure there are no curtains, blinds, or 
furniture  blocking the side or back of the de-
humidifier.  

 

Dirty filter. 

See the 

Cleaning The Air Filter 

section on 

page 13. 

 

The user set Humidity 
Level may not be set low 
enough. 

To reduce moisture, press the down arrow 
button to lower the percent  humidity desired in 
the room, or set the dehumidifier to 

CO 

for 

continuous operation. 

 

Doors and windows may 
not be closed tightly. 

Check that all doors, windows, and other 
openings are securely closed. 

 

Water is not draining 
through drain hose 

Make sure the drain is placed below the drain 
connector nozzle to allow gravity to drain the 
water (Refer to Gravity Drain Hose section in 
this manual). 

 

Room temperature is too 
low. 

Moisture removal is best at higher room tem-
peratures. Lower room temperatures will re-
duce the moisture removal rate. This model is 
designed to operate at temperatures above 
41°F. 

Filter Indicator is lit. 

Filter needs to be 
cleaned every 250 hours 
of use. 

Once filter has been cleaned, press the FIL-
TER button for 3 seconds to turn the filter 
indicator off. 

TROUBLESHOOTING 

7  

 

DEHUMIDIFIER OPERATON 

POWER ON/OFF (1) 

Once the unit is plugged in, the 

POWER INDICA-

TOR (10) 

will light.  Pressing the POWER button 

once will turn the unit ON and illuminate the 

digi-

tal display (13)

.  The fan will operate for 3 

minutes to draw air through the dehumidifier to 
properly sense relative humidity.  The display will 

    control panel

show the humidity level of the room in 

1

% incre-

ments, down to a minimum of 

30

%.  Pressing the 

Power button again will turn the display OFF and 
the unit will cease operating. 
 

HUMIDITY LEVEL (2) 

The humidity level can be set in 5% increments in 
a range from 35% to 80%.  The humidity setting is 
shown in the 

digital display (13).  

When the hu-

midity level of the room reaches the set level, the 
compressor will stop, but the fan will continue 
operating for 3 minutes. To set the unit to continu-
ous operation, press the down arrow button until 
the display shows 35%.  Press again and the 

display (13) 

will show CO. The 

Continuous indi-

cator (15) 

will light up on the control panel.  To 

leave continuous operation, press the UP arrow. 
To check the current humidity setting, press the 
up or down arrow. The display will show and set 
5% above or below the current settings. 
 

FAN SPEED (3) 

Press Fan Speed to toggle between Low, Med, 
and High fan speeds. Speed will be shown in 

FAN 

SPEED INDICATOR (9) 
 
BUCKET FULL INDICATOR (14) 

When the collection bucket is full, the 

BUCKET 

FULL indicator (14) 

will light up and you will hear 

an audible alarm. The audible alarm will last up to 
ten seconds The dehumidifier will not run until the 
bucket is removed, emptied and replaced. 
 

AUTO MODE (7) 

Press the 

AUTO button (7) 

to select AUTO Mode. 

When AUTO MODE is selected the unit will auto-
matically choose settings according to the current 
room humidity level. The 

AUTO indicator (8) 

will 

light up when selected. The set humidity level is 
not able to be changed in this mode. 
 

PUMP MODE (6) 

Press the 

PUMP button (6) 

to select Pump Mode. 

When PUMP MODE is selected the unit will pump 
the collected water out of the unit. Make sure the 
pump accessories are connected (refer to pages 
10 & 11) prior to using pump mode. When select-
ed the 

PUMP indicator (16)

 will light up. 

TIMER - DELAY START/AUTO ON (4) 

When the dehumidifier is off, it can be set to auto-
matically turn on in 30 minutes to 24 hours at the 
previous set mode and fan setting. To set the 
Auto-on Timer, press the 

TIMER (4) 

button on the 

control panel. Each touch of the 

+/- 

buttons on the 

 will change the timer setting in 30 min 

increments (.5 hours). After 10 hours each press 
of the + button will increase the timer in 1 hour 
increments. Once the timer is set, press the 

TIM-

ER (4) 

button once more to save the setting. The 

TIMER indicator (11) 

will light up at this time. 

 

TIMER - AUTO SHUT-OFF (4) 

When the dehumidifier is on, it can be set to auto-
matically turn off in 30 minutes to 24 hours. To set 
the Auto-off Timer, press the 

TIMER (4) 

button on 

the control panel. Each touch of the 

+/- 

buttons on 

the 

control panel

 will change the timer setting in 30 

minute increments (.5 hours). After 10 hours each 
press of the + button will increase the timer in 1 
hour increments. Once the timer is set, press the 

TIMER (4) 

button once more to save the setting. 

The 

TIMER indicator (11) 

will light up at this time. 

 

FILTER RESET (17) 

The 

FILTER RESET indicator (17) 

will light up 

when the filter needs cleaning. Remove the filter 
and clean accordingly. Replace the filter when 
finished and press 

FILTER (5) 

to reset the filter 

indicator. 
 

CONTROL PANEL LOCK (12) 

To lock the control panel, press the 

“+” and “-

” (2) 

keys at the same time for 3 seconds. Locking 

the control panel prevents someone from acci-
dentally changing the settings. When locked, the 

LOCK indicator (12) 

will light up. Hold the 

“+” 

and “-” (2) 

keys at the same time again for 3 

seconds to unlock the  control panel. 
 
 
 
 

NOTE

:  

 

Once  the set humidity level is reached, the 
compressor will shut off. The fan will contin-
ue to run for up to 3 minutes. 

 

Anytime the compressor stops running for 
any reason, it will not restart for a minimum 
of 3 minutes. This is a design feature to pro-
tect the compressor from damage. 

Summary of Contents for SG-DEH-70EIP-6

Page 1: ...RESS Soleus International Inc 20035 E Walnut Dr N City of Industry CA 91789 WEBSITE www soleusair com TEL 888 876 5387 SG DEH 70EIP 6 Portable Dehumidifier with Internal Pump Operating Instructions V...

Page 2: ...______ _____________________________________________________________________ _____________________________________________________________________ _____________________________________________________...

Page 3: ..._______________ _____________________________________________________________________ _____________________________________________________________________ NOTES 3 SAFETY INSTRUCTIONS IMPORTANT CAUTIO...

Page 4: ...Leave the dehumidifier in an upright position for 30 minutes before turning on DEFROST OPERATION The dehumidifier has a built in defrost control that senses frost buildup on the evaporator coils Duri...

Page 5: ...fier in the basement to help prevent moisture damage in the kitchen bathroom and spa exercise areas that have excessive mois ture to prevent moisture damage anywhere books or valuables are stored duri...

Page 6: ...vel Fan Noise Air is moving through the unit This is normal Water on the floor Hose connection may be loose Check the hose connection See the Drainage Section on page 8 Hose is attached but not draini...

Page 7: ...ow button until the display shows 35 Press again and the display 13 will show CO The Continuous indi cator 15 will light up on the control panel To leave continuous operation press the UP arrow To che...

Page 8: ...operation the FILTER RESET indicator will light up to remind you to clean and change the air filter It is recommended to periodically check the filter for excess dirt even if the FILTER RESET indicat...

Page 9: ...r installation or use of hose may result in water filling up the bucket and causing the unit to shut off Empty the water bucket if shut off occurs due to bucket full condition Place unit on even surfa...

Page 10: ...AL PUMP HOSE Step 1 Remove the bucket from the dehumidifier Fig 8 11 INSTALLING THE PUMP HOSE Step 4 Insert the pump hose onto the pump hose con nector Push the clamp towards the connector to se cure...

Reviews: