3)  Press the 

MODE 

button until the fan mode icon light up on the control panel display. 

4)  Select the fan speed by pressing the FAN button by using the Remote control. 
 

NOTE: 

It is not necessary for the exhaust hose and window kit to be installed to operate the unit in fan 

mode.  
  
 

Auto Mode 

1)  Install the exhaust hose and window kit properly (see pages 7  & 8 ). 
2)  Plug the Power Cord into an electrical outlet. 
3)  Turn on the unit by pressing the 

POWER 

button. 

4)  Press the 

MODE 

button on the remote control until the AUTO appears on the remote control LCD 

panel display.   

 

NOTE: 

During AUTO mode, the unit operates in 

FAN 

mode when the room temperature is below 68 

°

F,             

Dehumidifier 

mode when the room temperature is between 68

 

°

F to 80

 

°

F.  And 

Air Conditioner 

mode 

CONDENSATE EVAPORATION 
 
Emergency Condensate Holding Tank 

 

When the room temperature is low and the indoor humidity is high, the air conditioner may not be able to 
evaporate some of the moisture fast enough. When this happens, the water will accumulate in an emer-
gency condensate tank inside the unit. Once the emergency condensate tank is full, the unit will automati-
cally shut off and the led of 

BUCKET FULL 

will light up on the control panel display. To empty the con-

densate tank, pull the drain plug at the bottom back of the unit. You will need a small pan, approximately 
1” high to catch the water coming out of the condensate tank. Connect the supplied drainage hose to the 
back of the unit to aid in drainage into the pan. Once the condensate tank is drained, the unit will begin 
working within a few minutes. The emergency condensate tank is approximately 1.5 Liters of water. An-
other option is to purchase a small hose from a hardware store that can fit around the 5/8” drain plug on the 
back of the unit and drain the unit into a gravity drain or larger pan for continuous drainage. It is not ad-
vised to use continuous drainage when the room temperature is higher than 90

°

F . 

 
If you do not need the emergency tank emptied immediately simply leave the unit on. The fan in your air 
conditioner will continue to run to help evaporate the moisture as fast as possible. 

 

 

To resume operation quickly, empty the water container according to the following steps: 
1.  Turn the unit off

. Do not move the unit when the water container is full

2.  Place the drain pan accessory under the drainage port at the back of the unit. 
3.  Remove the rubber plug from the drain hole. The condensate water will drain out automatically. 
4.  When the drain pan is full, install the rubber plug back onto the drainage hole to stop the water flow. 
5.  Empty the drain pan. 
6.  Repeat steps 2-5 until all the water is emptied. 

NOTE: 

Once the water container has 

been emptied, install the rubber plug 
back onto the drain hole. It is not advised 
to use continuous drainage when the 
room temperature is higher than 90

°

F . 

Drain Hole 

Rubber Plug 

Summary of Contents for SE-PAC-08E9

Page 1: ...8 000 BTU Portable Air Conditioner Operating Instructions V 130711 Model No SE PAC 08E9 Reference No KY 80E9 3092402...

Page 2: ...ual in a safe place for future reference 1 Always place the unit on a level surface 2 Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual 3 M...

Page 3: ...or lower than the minimum operat ing temperature the air conditioner may not work properly PACKAGE CONTENTS MODEL NUMBER SE PAC 08E9 REFERENCE NUMBER KY 80E9 COOLING CAPACITY 8 000 BTU H DEHUMIDIFYING...

Page 4: ...rounded and they must be considered a shock hazards if exposed The cord shield must not be connected to ground or to any exposed metal The test and reset buttons on the LCDI Plug are used to check if...

Page 5: ...DIAGRAM Casters Louvers Remote Control Signal Receptor Control Panel on top Filter Compartment Remote Control Evaporator Air Intake Condenser Air Outlet Condenser Air Intake Drain Port Drain Hole Rub...

Page 6: ...ass doors up to 7 ft long approximate length MOUNTING THE EXHAUST HOSE Choose a suitable location near a grounded electrical outlet and suitable window or door Remove packaging and locate components E...

Page 7: ...and im ages show general directions for Soleus Air hose portable air conditioners WINDOW KIT INSTALLATION Optional Window Kit Adapter Extension Included The Window Kit Adapter Extension is an optiona...

Page 8: ...crews A Do not tighten the Wing Nuts B all the way make sure they are somewhat loose 4 Now place the Sliding Track Panel D over the Track Screw A on Hose Panel C1 5 Next take the other Hose Panel C2 a...

Page 9: ...mode The temperature indicator flashes to display the desired temperature setting After the temperature is set the unit will display this temperature setting until it is changed by the user The tem pe...

Page 10: ...OL TIMER ON TIMER OFF LCD DISPLAY POWER BUTTON MINUTE SELECTER SLEEP BUTTON HOUR SELECTER TEMP SETTING MODE BUTTON FAN SPEED OPERATING THE UNIT USING THE REMOTE CONTROL Remote Colors may differ from t...

Page 11: ...er low when pressing the FAN speed button on the remote control The speeds will cycle through in this order High Medium Low Auto Each change in speed will be asso ciated with a beep sound from the uni...

Page 12: ...e ranges from 61 F 88 F 16 C 31 C 6 Select the desired fan speed by pressing the FAN button by using the Remote control NOTE During hot days the unit will cool the room most efficiently by setting the...

Page 13: ...1 high to catch the water coming out of the condensate tank Connect the supplied drainage hose to the back of the unit to aid in drainage into the pan Once the condensate tank is drained the unit will...

Page 14: ...ghly dried 4 If the filter is torn or unusable order a new filter by calling the customer service number on the warranty page of this manual Clean the unit Housing 1 Keep the unit from being exposed d...

Page 15: ...ppearance parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus In ternational Inc Freight and Insurance cost for the warranty servic...

Reviews: