Auto Mode 

1)  Install the exhaust hoses and window kit properly (see pages 6 & 7). 
2)  Plug the Power Cord into an electrical outlet. 
3)  Turn on the unit by pressing the 

POWER 

button on the control panel. 

4)  Press the 

MODE 

button until the “

” icon appears on the control panel display. Select the fan speed 

by pressing the 

FAN  SPEED 

button.  

 

NOTE: 

During AUTO mode, the unit operates in 

Heating 

mode when the room temperature is below 68 

°

F,             

Dehumidifier 

mode when the room temperature is between 68

 

°

F to 80

 

°

F.  And 

Air Conditioner 

mode when 

the room temperature is above 80

 

°

F. 

 

Sleep Mode 

(This mode can only be selected when using the Remote control )  

1)  To set Sleep mode, make sure the unit is in Air Conditioner mode. 

2)  Press the 

SLEEP 

Button on the remote control. The “

” icon appears on the control panel display.  

3)  When in 

SLEEP 

mode, the fan will run on low to keep fan noise at a minimum.  

4)  When in Air Conditioner mode, the temperature setting will gradually increase to 2

°

F above the original set 

temperature for 6 hours.  After 6 hours the temperature setting will return to the set temperature. 

5)  When in Heating mode, the temperature setting will gradually decrease to 2

°

F below the original set tem-

perature for 6 hours.  After 6 hours, the temperature setting will return to the set temperature. 

6)  When in Dehumidifier mode, the temperature will not change when Sleep mode is selected. 

 

 
Compressor Indicator 

The “

” icon will light up on the control panel display when the compressor turns on. The “

” icon will 

turn off when the compressor shuts off. 
 

Emergency Condensate Holding Tank 

 

When the room temperature is low and the indoor humidity is high, the air conditioner may not be able to 
evaporate some of the moisture fast enough. When this happens, the water will accumulate in an emergency 
condensate tank inside the unit. Once the emergency condensate tank is full, the unit will automatically shut 

off and the “ 

” will appear on the control panel display. To empty the condensate tank, pull the drain plug 

at the bottom back of the unit. You will need a small pan, approximately 1” high to catch the water coming out 
of the condensate tank. Once the condensate tank is drained, the unit will begin working within a few minutes. 
The emergency condensate tank is approximately 2.0 Liters of water. Another option is to purchase a small 
hose from a hardware store that can fit around the 5/8” drain plug on the back of the unit and drain the unit into 
a gravity drain or larger pan for continuous drainage. It is not advised to use continuous drainage when the 
room temperature is higher than 90

°

F .

 

 
 

Summary of Contents for PH4-10R-01

Page 1: ...2006 Soleus Air International 10 000 12 000 BTU Portable Air Conditioner 10 000 12 000 BTU Heat Pump PH4 10R 01 PH4 12R 01 Operating Instructions Model No PH4 10R 12R 3092402...

Page 2: ...our portable air conditioner please read this owner s manual carefully Store this manual in a safe place for future reference 1 Always place the unit on a level surface 2 Never use or store gasoline o...

Page 3: ...NTS MODEL PH4 10R 01 PH4 12R 01 COOLING CAPACITY 10 000 12 000 BTU H HEATING CAPACITY 10 000 12 000 BTU H DEHUMIDIFYING CAPACITY 50 60 pts Day POWER COOLING 1200W 1350W HEATING 950W 1160W AIR FLOW VOL...

Page 4: ...ounded and they must be considered a shock hazards if exposed The cord shield must not be connected to ground or to any exposed metal The test and reset buttons on the LCDI Plug are used to check if t...

Page 5: ...ed window kit can be installed in sliding windows and sliding glass doors up to 8 ft long approximate length MOUNTING THE EXHAUST HOSES Choose a suitable location near a grounded electrical outlet and...

Page 6: ...6 DUAL HOSE WINDOW KIT INSTALLATION To quickly and efficiently cool a large area...

Page 7: ...7 WINDOW KIT ASSEMBLY...

Page 8: ...ke cover After installing the hose remove the square air intake cover on the back of the unit and install the square air intake vent with removable washable filter For Single Hose Window Kit Installat...

Page 9: ...TROL PANEL MULTI COLOR DISPLAY POWER BUTTON MODE BUTTON TIMER BUTTONS TEMP TIMER SELECTION FAN SPEED BUTTON TEMP SELECT AUTO A C DEHUM FAN HEAT FAN SPEED TIMER ON TIMER OFF TEMPERATURE AND TIMER INDIC...

Page 10: ...ously will change the temperature select between F and C 5 Timer To program the timer press the TIMER ON button until the display shows a flashing Press the or buttons to change the clock to the desi...

Page 11: ...room temperature is lower than 61 F Fan Mode 1 Plug the Power Cord into an electrical outlet 2 Turn on the unit by pressing the POWER button on the control panel 3 Press the MODE button until the icon...

Page 12: ...em perature for 6 hours After 6 hours the temperature setting will return to the set temperature 6 When in Dehumidifier mode the temperature will not change when Sleep mode is selected Compressor Indi...

Page 13: ...EMOTE CONTROL TIMER ON TIMER OFF LCD DISPLAY POWER BUTTON MINUTE SELECTER SLEEP BUTTON HOUR SELECTER TEMP SETTING MODE BUTTON FAN SPEED SWING LOUVER OSCILLATION OPERATING THE UNIT USING THE REMOTE CON...

Page 14: ...ge in speed will be as sociated with a beep sound from the unit The remote control will not display AUTO under the speed label Once Auto fan speed is selected the unit will beep and there will not be...

Page 15: ...dried 4 If the filter is torn or unusable order a new filter by calling the customer service number on the warranty page of this manual Clean the unit Housing 1 Keep the unit from being exposed direc...

Page 16: ...h of the case or other appearance parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna tional Inc Freight and Insurance cost...

Reviews: