background image

 

 

 

 

OPERATING INSTRUCTIONS FOR CONTROL PANEL BUTTONS

 

 

1)

 

Power On and Off 

-

 Press the 

POWER 

button once to manually turn the unit on. Press the 

POWER 

button once more to turn the unit off. 

 

2)

 

Mode Selection 

-

 Press the 

MODE

 Button repeatedly to cycle between the different modes: Heat 

mode, Air Conditioner (Cool) mode, Dehumidifier (Dehum) mode, Fan

-

only mode. Each press of the 

MODE button will light up a different indicator on the control panel. The exhaust hose and window kit 

must be installed when the unit is in Air Conditioner, Heater and Dehumidifier mode. When using the 

unit as a fan, the window kit is not required.

 

3)

 

Temperature 

-

 Select the desired temperature by pressing either the 

 or 

  

button when using the 

unit in Air Conditioner or Heat mode. The temperature indicator flashes to display the desired tempera-

ture setting. After the temperature is set, the unit will display this temperature setting until it is changed 

by the user. The temperature indicator display shows temperature in Fahrenheit. While the unit is 

plugged in, press and hold the 

 and 

 buttons to switch between Celsius and Fahrenheit.

 

4)

 

Fan Speed 

-

 

Press 

FAN 

button to choose fan speed in High, Medium or low.

 

Fan speed cannot be 

adjusted in Dehum Mode.

 

5)

 

Timer 

-

 

Press 

TIMER 

button to set the unit automatically turn ON or OFF. Use the 

 and 

 

buttons 

to program the hour increment. 

 

6)    

Bucket Full 

-

 When the unit cannot evaporate the collected moisture fast enough, the excess water 

will collect in a backup water tank located inside the unit. The BUCKET FULL indicator will light up.

 

7)   

Swing 

-

 Press the 

TIMER

 and 

FAN 

buttons at same time to active the auto swing function. 

 

Fan Speed 

 

Indicators

 

Air Conditioner 

Mode Indicator

 

Fan Mode 

Indicator

 

Power 

 

Indicator

 

Bucket Full

 

Indicator

 

Timer 

Indicator

 

Dehumidifier 

Mode

 

Heat Mode

 

Indicator

 

CONTROL PANEL

 

Swing Function

 

Sleep Mode

 

Indicator

 

Summary of Contents for LX-140 NT

Page 1: ...V180320 4010450 Air conditioner must be upright for 24 hours prior to operating This ensures that the compressor will function as intended...

Page 2: ...ays place the unit on a level surface 2 Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual 3 Maintain at least 20 inches 50 cm clearance spa...

Page 3: ...d setting These specifications are for reference only For actual data please refer to the rating label on the back of the unit If the environment temperature is higher than the max operating temperatu...

Page 4: ...xposed metal The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test 1 Plug power cord into wall outlet the LED light will turn on 2 Press TEST Button...

Page 5: ...PRODUCT DIAGRAM 16 Remote Control Battery Intake hose connector...

Page 6: ...idification and heating modes When the unit is operating in Fan Mode no outdoor air exchange takes place The window kit and exhaust hoses do not need to be installed when the unit is used as a fan The...

Page 7: ...Nuts after adjusting the length of the panel according to the height of the window 1 Using Panel B to connect Panel A C by placing the Wing Nut Base on Panel A C 3 Connect the exhaust hoses to the win...

Page 8: ...the window or door to adjust the length of the Window Kit Panels to fit the opening If necessary mark the kit and cut one end down to properly fit the opening 3 Twist the Exhaust Hose Connector over...

Page 9: ...After the temperature is set the unit will display this temperature setting until it is changed by the user The temperature indicator display shows temperature in Fahrenheit While the unit is plugged...

Page 10: ...LCD DISPLAY POWER BUTTON TIMER TEMP DECREASE TIMER TEMP INCREASE SLEEP MODE BUTTON TIMER BUTTON SWING BUTTON MODE BUTTON FAN SPEED REMOTE CONTROL...

Page 11: ...s the or to select your desired temperature setting The temperature on the LCD display on the remote control will increase or decrease accordingly 5 SLEEP MODE When in air conditioning mode press the...

Page 12: ...d window kit and keeping direct sunlight to a minimum will also improve the cool ing efficiency NOTE When the unit is running on air conditioning mode the exhaust hose is required and must be vented o...

Page 13: ...aid the effectiveness of the unit in removing the moisture from the room NOTE When the unit is running on dehumidifier mode the exhaust hose is required and must be vented outside using the supplied w...

Page 14: ...ll accumulate in an internal water tank inside the unit When this tanks becomes full the unit will automatically shutdown and illumi nate the Bucket Full indicator HOW TO INSTALL CONTINUOUS DRAIN OPTI...

Page 15: ...he unit 3 Remove the drain plug from the condensation drain hole The condensate water will drain out automati cally 4 When the drain pan is full install the drain plug back onto the condensation drain...

Page 16: ...ng 1 Keep the unit from being exposed directly to the sun to prevent color fading 2 Clean the surface with a damp cloth and dry it with a soft towel Storing the Unit for an Extended Period of Time or...

Page 17: ...ly keeping it as short and free of curves as possible Check and remove anything obstructing air discharge During operation there is an unpleasant smell in the room Air filter is dirty Remove air filte...

Page 18: ...it on and off to remove error code If this code appears again please call customer service at 877 976 5387 E2 Indoor Temperature Sensor Failure Turn the unit on and off to remove error code If this co...

Page 19: ...sions in the instructions Damage to the finish of the case or other appearance parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by SoleusA...