LCDI POWER CORD AND PLUG

 

 

This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and 
plug as  required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord 
with no termination on the load side and a LCDI attachment plug on the line side. 
 
The LCDI power cord and plug will remove the supply source via electrical disconnect (circuit trip) if the 
nominal current leakage between the cord shield and either load conductor exceeds a predetermined value. The 
cord will remain de-energized until the device has been manually reset. This is intended to reduce the risk of a 
fire in the power cord or combustible materials nearby. The cord shields are not grounded and they must be 
considered a shock hazards if  exposed. The cord shield must not be connected to ground or to any exposed 
metal. 
 
The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly. To test:  
 

1. Plug power cord into wall outlet 
2. Press TEST Button, circuit should trip, cutting power to the air conditioner  
3. Press RESET button for use 

 
If test button is pressed and unit  can still be turned on, current leakage has been detected. Do not use the air            
conditioner or attempt to reset the LCDI Plug. Contact Soleus Air Customer Service for troubleshooting                      
recommendations.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

WARNING: 
 
1.  DO NOT press the TEST button while the air conditioner is operating. 
2.  The TEST and RESET buttons should not be used as 

ON

” 

and 

OFF

” 

switches. 

3.  The cord and plug are not intended to offer protection to externally connected loads or supply circuits. 
4.  The cord and plug are intended for indoor use only. 

RESET 

TEST 

 4 

Summary of Contents for KY5-110

Page 1: ...BTU Portable Air Conditioner Evaporative Technology Operating Instructions Model No PE8 11R 32 3092402 Reference No KY5 110...

Page 2: ...nce 1 Always place the unit on a level surface 2 Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual 3 Maintain at least 10 inches 25 cm clea...

Page 3: ...re is higher than the max operating temperature or lower than the minimum operating tem perature the air conditioner may not work properly PACKAGE CONTENTS Portable Air Conditioner Exhaust Hose 1 Hose...

Page 4: ...nded and they must be considered a shock hazards if exposed The cord shield must not be connected to ground or to any exposed metal The test and reset buttons on the LCDI Plug are used to check if the...

Page 5: ...M Casters Louvers Control Panel and LED display Air Filter Compartment and Air Intake 5 Air Filter Compartment and Air Intake Power Cord Wrap Remote Control Holder Exhaust Outlet Drain Plug Carry Hand...

Page 6: ...tion near a grounded electrical outlet and suitable window or door Remove packaging and locate components Extend both ends of the exhaust hose approximately 6 inches Screw the window kit adapter onto...

Page 7: ...7 NOTE The Portable Air Conditioner above may differ from the unit described in this manual The above directions and images show general directions for Soleus Air hose portable air conditioners...

Page 8: ...ews A Do not tighten the Wing Nuts B all the way make sure they are somewhat loose 4 Now place the Sliding Track Panel D over the Track Screw A on Hose Panel C1 5 Next take the other Hose Panel C2 and...

Page 9: ...d by the user The temperature indicator display shows temperature in Celsius or Fahrenheit Press the and simultaneously to change between Celsius and Fahrenheit 5 Auto on Timer To program the Auto on...

Page 10: ...exhaust hose is required and must be vented outside using the supplied window kit Dehumidifier Mode 1 Install the exhaust hose and window kit properly see pages 7 8 2 Plug the Power Cord into an elec...

Page 11: ...nit and drain the unit into a gravity drain or larger pan for continuous drainage It is not advised to use continuous drain age when the room temperature is higher than 90 F If you do not need the eme...

Page 12: ...nel shows temperature in Celsius or Fahren heit Press the C F button to change the temperature select between Celsius and Fahrenheit 5 Auto on Timer To program the Auto on timer press the TIMER button...

Page 13: ...ied 4 If the filter is torn or unusable order a new filter by calling the customer service number on the warranty page of this manual Clean the unit Housing 1 Keep the unit from being exposed directly...

Page 14: ...rance parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna tional Inc Freight and Insurance cost for the warranty service AL...