background image

CONTROL PANEL & DISPLAY

When pressing key is valid, buzzer makes a sound, indicated light indicates relevant state, system  will last for 

2 seconds.

OPERATING INSTRUCTIONS

l.

3.MODE Button

4. Fan 

S

peed

When the unit is running in Cool or F

a

n mode, press the Fan speed Button to select the fan speed 

 in High, 

Middle, Low , Auto.

In cool mode, it can decrease the temperature of the room, and  make people very 

comfortable.

ON/OFF Button

2. "+","-" Button

In COOL mode, press "-" once, the set temperature will decrease 1  

, press "+" once, the set temperature will 

 C( F)

Receiver window

LED window

DRY mode light

Temperature selection button

COOL mode light

MODE button

FAN mode light

FAN Speed light

ON/OFF button

Fan speed button

 

Button

CONTROL PANEL DISPLAY & OPERATING INSTRUCTIONS

        

   

6. Louver Direction 

This unit has 4-Way directional louvers. 

Use the louver guides to direct air where

cooling or fanning is needed most.Hold the 

louver and adjust the air flow direction,

as shown in the right diagram.

5.Water Full

When COOL or DRY is running, condensate will drain to 

 water tank. When water tank is filled, buzzer will sound 8

  times, LED screen show error code ‘H8’.

In this case, reference page 8 to drain out water intank.

Press the button once to manually turn the uni

on. Press once more to turn the unit off.

Press MODE Button repeatedly to cycle between the modes:Cooling,Dry,and Fan only mode. 

Each press of 

the MODE 

button will light up a different lights on the control panel. The exhause 

hose and window kit must

be installed when the 

unit is in Cool or Dry mode. When using the unit  as a fan, it is unnecessary to keep the

exhaust hose and window kit connected to the unit. 

Hold this hand grip to adjust the

direction of Horizontal Louvers 

Hold this hand grip to adjust the

direction of Vertical Louvers 

increase 1C ( F). The set temperature range from 16 C to 30 C(61 F to 86 F).

 

 1

0

Summary of Contents for KY-101

Page 1: ...10 000 BTU Portable Air Conditioner Operating Instructions Model No SG PAC 10E2 KY 101...

Page 2: ...manual carefully Store this manual in a safe place for future reference 1 Always place the unit on a level surface 2 Never use or store gasoline or other flammable vapor or liquid near this unit unles...

Page 3: ...hazards if exposed The cord shield must not be connected to ground or to any exposed metal The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test 1 P...

Page 4: ...1 5V INCLUDE Window ExhaustAdapter B SUGGESTED TOOLS FOR WINDOW PANEL INSTALLATION 1 Screwdriver medium size Phillips 2 Tape measure or ruler 3 Knife or scissors 4 Saw In the event that the window pa...

Page 5: ...t 6 Vertical louvers 7 Horizontal louvers 8 Wheel 9 Air inlet 10 Grille 11 Air outlet 12 Air inlet 13 Power cord hook 14 Power cord 15 Windowexhaustadapter A 16 Exhaust hose 17 Window exhaust adapter...

Page 6: ...w Exhaust Adapter A 1 Window Exhaust Adapter B 1 Window Exhaust Adapter C 1 Remote Control AAA Batteries 2 batteries Window Kit 3 Sliding Panels 1 single hose panel 2 extension panels Drain Hose Assem...

Page 7: ...Attach the hooks to the back of air conditioner with the screws hook screw Wind the power cord around the power cord hooks INSTALLATION OF THE POWER CORD HOOK 7...

Page 8: ...e a suitable location near a grounded electrical outlet and suitable window or door Remove packaging and locate components x Extend both ends of the exhaust hose approximately 6 inches x Screw the win...

Page 9: ...s flat as possible The less angles and bends in the hose the better the unit will perform If bending or an angle is necessary use single 90 angles like the pictures above Multiple bends will decrease...

Page 10: ...guides to direct air where cooling or fanning is needed most Hold the louver and adjust the air flow direction as shown in the right diagram 5 Water Full When COOL or DRY is running condensate will dr...

Page 11: ...nal receiver window A n o t t u b d e r i s e d e h t s s e r p d n a beep will sound when the unit re ceives the signal blocks the signal receiver window CAUTION its operation If necessary to close t...

Page 12: ...cycle through low medium and high fan speeds The small fan icons will light up depending on which speed is selected The more fan icons light up the higher the speed The fan icons are located on the L...

Page 13: ...button to cancel the timer 6 Sleep Mode Press the SLEEP mode button to engage SLEEP mode Sleep mode automatically raises the set temperature by 2 F after one hour and 4 F after two hours This feature...

Page 14: ...s below 1 Remove the pre installed Drain Cap from the unit See Below 2 Attach the Clamp with the provided Screw See Below 3 Attach the Drain Hose to the Drain Port using the Drain Hose Clip Insert the...

Page 15: ...ied 4 If the filter is torn or unusable order a new filter by calling the customer service number on the warranty page of this manual Clean the unit Housing 1 Keep the unit from being exposed directly...

Page 16: ...T button will not stay engaged discontinue use of the air conditioner and contact a qualified service technician TROUBLESHOOTING The Air Conditioner does not cool as it should Airflow is restricted Th...

Page 17: ...for 10 minutes and then turn on the unit If E5 is still dis played contact customer service TROUBLESHOOTING CONT The LCD Display is showing H8 The backup water tank is full x Drain the water tank x I...

Page 18: ...appearance parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna tional Inc Freight and Insurance cost for the warranty serv...

Reviews: