Introduction 

 

Room air conditioners cool, dehumidify, and filter air inside 
your home.  Heat pump and electric heat models offer both 
heating and cooling.  Opening sections of manual provide 
general information for all room air conditioner models. 

Operating Controls 

section describes operation of controls 

for each model.  After reading the opening sections, turn to 

Operating Controls 

section and find the panel layout that 

matches the model of your unit. 
 
Read entire manual thoroughly before beginning installation 
and operation of your new room air conditioner.  Be sure you 
have all necessary tools and materials on hand for the job. 
Study illustrations to familiarize yourself with important details 
of the installation process. Review manual for operating 
instructions. 
 
 

NOTE 

1.  Mechanical experience is required to install air conditioner. 
2.  Installation can take from 1 to 3 hours, depending on installer’s knowledge and skill. 
3.  If you encounter problems during installation, call our Technical Support and Warranty Service at 

1-888-8-SOLEUS.  If your problem cannot be resolved by phone, contact an authorized Soleus Air 
brand servicer. Contact and service will be at your expense. 

 
 
 
 
 

 

         

   

Safety Information 

 

Be sure electrical service is adequate for chosen model of air conditioner.  Complete electrical rating for 
unit is found on serial plate located behind front grille.  Electrical outlet must be close enough to unit for 
power cord to reach without strain.  Air conditioner should be the only appliance on individual circuit. 
 
For personal safety and to avoid possible damage to appliance or home, observe all safety instructions 
highlighted by symbol shown below. 

 
 
 

               RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION.

 

 
After installing unit, reread instructions to ensure each step is complete and that all parts are fastened in 
place. For best results and to minimize installation time, perform all procedures in the order shown. 

 
 
 
 
 

 

 

Summary of Contents for KC-30H

Page 1: ...TU Room Air Conditioner with Heat Pump OPERATING AND INSTALLATION MANUAL Models KC 30H KC 35H Thank you for selecting Soleus Air To ensure proper operation please read this manual and keep it for futu...

Page 2: ...INSTALLATION INSTRUCTIONS 12 GENERAL OPERATING INSTRUCTIONS 13 OPERATING CONTROLS 14 BEFORE CALLING SERVICE 15 WHEN SERVICE IS REQUIRED 15 ANY QUESTIONS 15 THROUGH THE WALL INSTALLATION INSTRUCTIONS...

Page 3: ...an take from 1 to 3 hours depending on installer s knowledge and skill 3 If you encounter problems during installation call our Technical Support and Warranty Service at 1 888 8 SOLEUS If your problem...

Page 4: ...e this device for unattended cooling of persons or animals unable to react to product failure Failure of unattended air conditioner may result in extreme heat in area intended for cooling causing heat...

Page 5: ...manual or in the mounting kit assembly Follow these instructions carefully Keep these instructions with this manual for future reference Your unit will be one of the following three designs Unit with...

Page 6: ...eaningandpolishingcompoundsarenot recommended as they may damage plastic surfaces Air Filter Cleaning A dirty air filter reduces operating efficiency of unit Filter should be inspected at least once e...

Page 7: ...Do not use an extension cord Free movement of air in room to be cooled A large enough opening for the air conditioner Adequate wall support for weight of air conditioner Air conditioner weighs betwee...

Page 8: ...rements are listed in the chart below Follow the requirements for the type of plug on the power supply cord A 27 min 68 6 cm B 16 min 41 3 cm A 16 40 6 cm B 22 57 5 cm C Wood thickness A B B C C A Pow...

Page 9: ...se leakage current If the cord is crushed the electronics detect leakage current and power will be disconnected in a fraction of a second To test your power supply cord 1 Plug power supply cord into a...

Page 10: ...gently Be sure your air conditioner cabinet does not fall out of the opening during installation or removal The location where the power cord exits the air conditioner should be no more than 4 ft 122...

Page 11: ...Attach foam adhesive seal along the bottom of the curtain bottom channel Install Cabinet into Window Handle air conditioner gently Be sure your air conditioner cabinet does not fall out of the opening...

Page 12: ...p of lower window and against upper window sash 3 Use a drill bit to drill a starter hole through the hole in the bracket and into the window sash 4 Attach window lock bracket to window sash with 10 x...

Page 13: ...all opening Square and level frame 6 Attach frame securely to the wall Install Cabinet into Wood Frame 1 Insert cabinet into the framed wall opening The top of the cabinet should extend 13 mm into the...

Page 14: ...ol knobs on some models NOTE For through the wall installations if needed install molding around room side of cabinet 7 Plug into a grounded 3 prong outlet 8 Press RESET on the power supply cord plug...

Page 15: ...om the indoor air However in very humid conditions excess amounts of water may drip off the unit chassis If this proves to be a problem install the condensate drain cup included with the unit to route...

Page 16: ...lters and circulates room air with the fan running continuously on high speed Also heats while the compressor or electric heater is running Select this setting for maximum air circulation and heating...

Page 17: ...for low outdoor temperatures Clean air filter by vacuuming or washing with water and mild soap Turning Temperature Control to warmer setting reduces occurrence and duration of frost FROST ON OUTDOOR...

Page 18: ...tructions All GREE brand Compact RoomAir Conditioners feature a slide out chassis Chassis and front cover must be re moved from outer case for installation In order to reinstall the chassis and re att...

Page 19: ...g Place outer case in opening flush against one side of opening Use carpenter s level and ensure case is level from side to side and has a 3 8 inch slope from front to back back of case must be 3 8 in...

Page 20: ...ust be made in wall opening to ensure free air flow to the side louvers This can be accomplished by chamfering the vertical portions of the outside opening as shown Ventilation louvers on top of case...

Page 21: ...ling AMPS 4 8 4 6 5 9 5 5 Cooling Watts 970 990 1210 1235 Cooling EER 9 8 9 4 Heating AMPS 4 5 4 2 5 8 5 1 Heating Watts 850 870 1100 1140 Heating EER 9 8 9 2 Electric Heat AMPS 15 6 16 15 6 16 Electr...

Page 22: ...e neglect accident incorrect power line voltage fire flood or other Acts of God or normal wear and tear Warranty service must be performed by a qualified HVAC contractor Soleus maintains a centralized...

Reviews: