background image

WARRANTY 

 

One Year Limited Warranty 
 

Soleus International Inc. warrants the accompanying Soleus Air PH3-12R-03 Portable Air Conditioner with Heat Pump 
technology to be free of defects in material and workmanship for the applications specified in its    operation instruction 
for a period of ONE (1) year from the date of original retail purchase in the United States. 
 
If the unit exhibits a defect in normal use, Soleus International Inc. will, at its option, either repair or replace it, free of 
charge within a reasonable time after the unit is returned during the warranty period. 
 
As a condition to any warranty service obligation, the consumer must present this Warranty Certificate along with a 
copy of the original purchase invoice. 
 

THIS WARRANTY DOES NOT COVER:

 

• 

Damage, accidental or otherwise, to the unit while in the possession of a consumer not caused by a defect in 
material or workmanship.  

• 

Damage caused by consumer misuse, tampering, or failure to follow the care and special handling provisions 
in the instructions. 

• 

Damage to the finish of the case, or other appearance parts caused by wear. 

• 

Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna-
tional Inc. 

• 

Freight and Insurance cost for the warranty service. 

 
ALL WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO 
ONE-YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY

. SOLEUS INTERNATIONAL INC.

  

DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES AND IN NO EVENT 
SHALL SOLEUS INTERNATIONAL INC’S LIABILITY EXCEED THE RETAIL VALUE OF THE UNIT FOR 
BREACH OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THIS UNIT. 
 

This warranty covers only new products purchased from our authorized dealers or retailers. It does not cover used, sal-
vaged, or refurbished products. 

 
As some states do not allow the limitation or exclusion of incidental or consequential damages, or do not allow  
limitation on implied warranties, the above limitations and exclusions may not apply to you.  This warranty gives you 
specific legal rights, and you may also have other rights that vary from state to state. 
 

For Technical Support and Warranty Service 

Please Call (888) 876-5387  
 
Or Write To: 
Soleus International Inc. 
20035 E. Walnut Dr. N. 
City of Industry, CA 91789 

www.soleusair.com

 

 16 

Summary of Contents for HCA-P12HP-A

Page 1: ...2008 Soleus Air International Portable Air Conditioner and Heater With Heat Pump Technology PH3 12R 03 Operating Instructions Model No PH3 12R 03 3046364...

Page 2: ...s manual carefully Store this manual in a safe place for future reference 1 Always place the unit on a level surface 2 Never use or store gasoline or other flammable vapor or liquid near this unit un...

Page 3: ...able Air Conditioner Exhaust Hoses 1 Hose Adapters 1 Window Kit Adapter 1 Remote Control AAA Batteries 2 Window Kit 2 Sliding Panels 1 single hose panel 2 extension panels Owner s Manual 3 MODEL PH3 1...

Page 4: ...louvers C Air outlet D Horizontal air louvers E Casters F Power Cord Plug BACK A Hot air outlet grill B Lower air inlet grill ACCESSORIES Flexible exhaust hose with 2 adapters 3 piece set stretches f...

Page 5: ...ir outlet on the back of the unit The exhaust hose should be kept as short and straight as possible Prevent any sharp bends in the exhaust hose as this will trap hot exhaust air The hot exhaust air ca...

Page 6: ...nded and they must be considered a shock hazards if exposed The cord shield must not be connected to ground or to any exposed metal The test and reset buttons on the LCDI Plug are used to check if the...

Page 7: ...window kit is not long enough connect the extra window kit panel to fit the opening Mark and cut down a single panel of the window kit if neces sary Place the window kit between the window and the win...

Page 8: ...tioner above may differ from the unit described in this manual The above directions and images show general directions for all Soleus Air single hose portable air conditioners When using to a sliding...

Page 9: ...Dehumidify Mode D Fan Mode E Heat Mode F Fan Speed Low High Me dium G Temperature H Swing Mode I Sleep Mode J Clock and Timer K Timer On L Timer Off M Compressor is on CONTROL PANEL DISPLAY OPERATING...

Page 10: ...ttons simultaneously on the control panel to select the desired temperature setting 5 Timer To program the timer press the TIMER ON button until the display shows a flashing Press the or buttons to ch...

Page 11: ...indow kit Dehumidifier Mode 1 Install the exhaust hoses and window kit properly see pages 7 8 2 Plug the Power Cord into an electrical outlet 3 Turn on the unit by pressing the POWER Button on the con...

Page 12: ...MODE button until the icon appears on the control panel display Select the fan speed by pressing the FAN button NOTE During AUTO mode the unit operates in Heating mode when the room temperature is bel...

Page 13: ...working within a few minutes The emergency condensate tank holds approximately 1 5 Liters of water Another option is to pur chase a small hose from a hardware store that can fit around the 5 8 drain...

Page 14: ...ect your desired temperature setting The temperature on the multi color display on the control panel will increase or decrease accordingly Pressing the F C button will change the temperature select be...

Page 15: ...the filter and dry it thoroughly out of sunlight 3 Slide the filter back into the filter compartment after it is thoroughly dried 4 If the filter is torn or unusable order a new filter by calling the...

Page 16: ...ase or other appearance parts caused by wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna tional Inc Freight and Insurance cost for the w...

Reviews: