background image

 

 15 

 

USING YOUR AIR CONDITIONER 

Electronic Control Panel & Remote Control 
 
 
 

 

1. 

Power Button: 

Turns the air conditioner on and 

off 

2. 

Digital Display: 

Under ON status without timer

setting,the operation mode is Auto,

 

Cool, Energy 

Saver or Dry mode,and the set temperature will be

displayed.

Under ON status without timer setting, the 

operation mode is fan mode and the ambient 

temperature

 will be displayed

.  

Time will be displaye

d

 under timer setting or timer

preview

 

 

3. 

Temperature Set: 

Use these buttons on the con-

trol panel and remote to increase or decrease the 
Set Temperature (the desired room temperature) 
in cooling

,

energy saver 

and dry 

mode. The 

SET

light 

will light up when setting the temperature 

4. 

Timer Set: 

Use these buttons on the control 

panel and remote to set the Timer. Each press of 
the Timer (

DELAY

) buttons will increase or de-

crease the timer. For timer instructions see #7. 

5. 

Fan Speed & Auto Fan

: Use the fan speed but-

tons to change the fan speed. Choose between 
low, medium, high, and Auto. 

                                      

6. 

Mode Button: 

Press the mode button to cycle 

through the various modes: Cooling, Energy 
Saver, Fan only, Dry (Dehumidifier)

 and Auto

7. Auto-on 

Timer: 

When the air conditioner is off, it 

can be set to automatically turn on in 0.5-24 hours 
at the previous set mode and fan setting. To set 
the Auto-on Timer, press the 

TIMER 

button on the 

unit or remote control. 

The timer can be set in 0.5 

The Set light will turn on while setting.

 

Auto-off Timer: 

When the air conditioner is on, it 

can be set to automatically turn off in 0.5-24 
hours. To se

t

 the Auto-off Timer, press the 

TIMER 

button on the unit or remote control. 

The timer 

 

can be set in 0.5 hour increment below 10 hours

and in 1 hour increment for 10 hours or above.

The 

SET 

light will turn on while setting. 

• 

To see the remaining time, press the 

TIMER 

Button. To change the timer setting use the 

/

 on the unit or the +/- buttons on the 

remote. 

• 

   

During preview of timer or timer setting,

press Timer button on the panel or remote 

8. 

Filter Check: 

After the fan rotates for 250 total 

hours, the filter check light will turn on to remind 
the user to clean the filter. Press the Filter check 
button once the filter is cleaned to reset the re-
minder.

 

Air Conditioner Controls 

NOTE: This display always shows the room temperature 

in Fan

Mode 

except when setting the Set temperature or the Timer. 

When the light is on the unit is in 

temperature or timer set mode. 

Normal Operating Sounds 

• 

You may hear a pinging noise caused by water 
hitting the condenser, on rainy days, or when the 
humidity is high. This design feature helps re-
move moisture and improve efficiency.  

• 

You may hear the thermostat click when the com-
pressor cycles on and off. 

• 

Water will collect in the base pan during rain or 
days of high humidity. The water may overflow 
and drip from the outside part of the unit. 

• 

The fan may run even when the compressor is 
not on. 

hour increment below 10 hours and in 1 hour

increment for 10 hours or above.

controller to cancel the timer setting.

Summary of Contents for GM-WAC-15ESE-C

Page 1: ...Models GM WAC 15ESE C GM WAC 18ESE C Electronic Window A C Operating Instructions ...

Page 2: ......

Page 3: ...ead this owner s manual carefully Store this manual in a safe place for future reference Your safety and the safety of others is very important to us Please pay attention to all safety messages outlined in this owner s manual WARNING To reduce the risk of fire electrical shock or injury when using your air conditioner follow the following basic precautions 2 This is a safety alert symbol This symb...

Page 4: ...ord must be replaced if it fails to trip when the TEST button is pressed and the unit fails to reset Do not use the power supply cord as an ON OFF switch The power supply cord is designed as a protection device A damaged power supply cord must be replaced with a new power supply cord from Soleus Air Powered by Gree The power supply cord contains new user serviceable parts Opening the tamper resist...

Page 5: ...es 2 Top Mounting Rail Foam Top Mounting Rail Seal Strip Accordion Panels 2 Side Retainer 2 Window Sash Seal Foam Seal for Bottom Rail Owner s Manual 4 SEAL BOTTOM RAIL TO UNIT SIDE RETAINER FRAME ASSEMBLY LEFT FOAM GASKET TOP ANGLE FRAME ASSEMBLY RIGHT SAFETY LOCK AND 3 4 ROUND HEAD SCREW 1 2 LONG SCREWS AND LOCKNUTS LOCKNUT 3 4 LONG FLAT HEAD BOLT WINDOW SUPPORT BRACKET WINDOW SASH SEAL SILLANGL...

Page 6: ...rrent Cooling Amperage 12 8 1 8 8 EER C O P 10 7 10 7 10 7 Noise Level dB A H M L 58 56 54 58 56 54 CFM H M L 470 430 390 470 430 390 Dehumidifying Capacity 100 Pints per day 132 Pints per day Product Dimensions W x H x D 23 625 x 17 75 x 25 5 23 625 x 17 75 x 25 5 Package Dimensions W x H x D 28 25 x 20 x 26 125 28 25 x 20 x 26 125 Net Gross Weight Lbs 108 120 113 125 Refrigerant Type R 410A R 41...

Page 7: ...ioner to tilt enough for proper drainage See FIG 2 Prior to Installing the Air Conditioner 1 Check for anything that could block airflow Check the area outside of the window for things such as shrubs trees or awnings Check the inside area to make sure curtains drapes or blinds will not prevent proper airflow 2 Check the available electrical outlet The power supply must be the same as shown on the ...

Page 8: ...ove and place to the side 3 Locate the four faceplate screws and remove These screws will need to be re installed prior to mounting the air con ditioner FIG 2 above 4 After removing the screws gently pull away the faceplate from the air conditioner cabinet FIG 3 4 5 Remove the two control panel screws from the front panel FIG 5 7 FIG 1 FIG 5 FIG 2 FIG 1 FIG 3 FIG 4 ...

Page 9: ...remove and place to the side 3 Locate the four faceplate screws and remove These screws will need to be re installed prior to mounting the air con ditioner FIG 2 above 4 After removing the screws gently pull away the faceplate from the air conditioner cabinet FIG 3 4 5 Remove the two control panel screws from the front panel FIG 5 8 FIG 2 FIG 1 FIG 3 FIG 4 FIG 5 ...

Page 10: ...WINDOW MOUNTING REMOVE CHASSIS 6 Remove the screws from the right side of the cabinet FIG 7 7 Hold the cabinet while pulling on the base handle to carefully remove the unit Do not pull or lift near the top of the unit FIG 8 9 FIG 7 FIG 8 ...

Page 11: ... screws Top Angle Rail and Side Bracket Installation 1 Place the air conditioner on a hard flat surface 2 Locate the foam gasket and top angle rail 3 Attach the foam gasket to the top angle rail 4 Install top angle side to cabinet as shown in FIG 7 5 Slide the I section of the window panel into the side bracket of the cabinet FIG 8a Do this for both sides 6 Insert top and bottom legs of window fil...

Page 12: ... the cabinet as shown below 4 Tighten all 6 bolts securely Extend the Accordion Panels 1 Carefully raise the window to expose the accordion panel and panel frame Loosen the locking screws so the accordion panels slide easily 2 Extend each panel to completely fill the width of the window Tighten the locking screws when the panels are fully extended Install the Window Lock and Sash Seal 1 Trim the s...

Page 13: ...all as specified below MAX WALL THICKNESS 8 IMPORTANT The side louvers must never be blocked NOTE All parts needed for Thru The Wall Installation are provided except a wood frame shims and 10 wood screws 10 1 long minimum Select a wall surface that 1 Does not support major structural loads such as the frame construction at ends of windows and under truss bearing points etc 2 Does not have plumbing...

Page 14: ...be flush with the dry wall NOTE If wall thickness is 8 1 2 or more add aluminum flashing over the bottom of the frame opening to assure water is unable to enter the area between the inner and outer wall Prepare and Install the Cabinet 1 Slide the chassis from the cabinet Refer back to the REMOVE CHASSIS instructions and FIG 1 6 in the WINDOW MOUNTING SECTION 2 Place the cabinet into the opening wi...

Page 15: ...NSTRUCTION 1 Cut or build a wall opening in the masonry wall similar to the frame construction refer to the THRU THE WALL installation for a wall thickness greater than 8 1 2 2 Secure the cabinet in place using masonry nails or masonry anchor screws Or build a frame using the instructions found in the THRU THE WALL installation section 3 Make sure the masonry above the cabinet is supported well Us...

Page 16: ...et light will turn on while setting Auto off Timer When the air conditioner is on it can be set to automatically turn off in 0 5 24 hours To set the Auto off Timer press the TIMER button on the unit or remote control The timer can be set in 0 5 hour increment below 10 hours and in 1 hour increment for 10 hours or above The SET light will turn on while setting To see the remaining time press the TI...

Page 17: ...tioner will cool the area depending on the location and set temperature of the remote control Take the remote control with you so the air conditioner cools the room to your loca tion The Remote must be in line of site of the A C for iFeel to operate correctly 7 SLEEP MODE Press the SLEEP button to turn SLEEP mode on or off SLEEP mode is set to off automatically When SLEEP mode is selected the time...

Page 18: ...and buttons a the same time 11 DISPLAY LIGHTS Hold the and FAN buttons to turn the light s on the display ON or OFF This can be done when the unit is on or off 12 ENERGY SAVER MODE When the unit is in energy saver mode the Energy Saver light will turn on In Energy Saver mode the unit will turn off once the room is cooled to the user set temperature The fan will also be off at this point The unit w...

Page 19: ...the Fan to Low with the temperature set in the middle NOTE If the air conditioner is off and is then turned on while set to a Cool setting or if turned from a fan setting to a Cool setting it may take approximately 3 minutes for the compressor to start and cooling to begin Energy Saver Mode Controls the Fan On The fan will cycle on and off with the compressor This results in winder variations of r...

Page 20: ...d Tear To minimize wear and tear on the air condi tioner always wait at least 3 minutes before changing modes This will help prevent the compressor from overheating and the circuit breaker from tripping Cabinet Cleaning To clean the air conditioner cabinet Unplug the air conditioner to prevent shock or a fire hazard The cabinet and front panel of the air conditioner may be dusted with an oil free ...

Page 21: ...ce technician TROUBLESHOOTING The Air Conditioner does not cool as it should Airflow is restricted The temperature control may not be set correctly The air filter is dirty The room may be too warm Cold air is escaping The Cooling Coils are frozen Make sure there are no curtains blinds or furniture blocking the front of the air conditioner Lower the set thermostat tempera ture Clean the filter See ...

Page 22: ...roper water drainage make sure the air conditioner is slightly tilted downward from the front of the unit to the rear Water collects in the base pan Moisture removed from the air is draining into the base pan This is normal for a short period in areas with low humidity and nor mal for a longer period in areas with high humidity Digital Display reads F1 F2 or FJ A sensor has failed Contact customer...

Page 23: ...e performed by a qualified HVAC contractor Soleus maintains a centralized service network to provide parts and assist in resolving service problems if difficulties are encountered Soleus agrees to provide service information sell repair parts and reimburse the dealer serviceman for parts in accordance with Soleus International s Policies and Procedures SOLEUS INTERNATIONAL MAINTAINS THAT ALL WARRA...

Page 24: ...66129908033 ...

Reviews: