background image

IMPORTANT SAFETY INSTRUCTIONS 

 

NOTE:

  The WARNING instructions issued in this manual are not meant to cover all possible conditions 

and situations that may occur.  It must be understood that common sense, caution and care are factors 
that must be used when installing, maintaining, or operating the dehumidifier. Failure to install, maintain, 
and/or operate the equipment according to the manufacturer’s instructions may result in conditions which 
can produce bodily injury and/or property damage.  Contact your dealer, service agent or the 
manufacturer about any problems or conditions you do not fully understand. 
 
FOR YOUR SAFETY – To reduce the risk of fire or explosion, do not store or use gasoline or other 
flammable vapors or liquids in the vicinity of this dehumidifier. 
 
ELECTRICAL SERVICE INFORMATION – To reduce the risk of fire, electric shock or personal injury, all 
wiring and grounding must conform to the latest edition of Local and National Electrical Codes.  It is the 
customer’s responsibility to have the wiring and fuses checked by a qualified electrician to make sure 
adequate electrical power is available. 
 
GROUNDING INSTRUCTIONS – Improper connection of the equipment-grounding conductor can result 
in a risk of electrical shock.  Check with a qualified electrician or servicemen if you are in doubt as to 
whether your appliance outlets are properly grounded. 
 
This dehumidifier must be grounded.  In the event of a malfunction or breakdown, grounding will reduce 
the risk of electrical shock by providing a path of least resistance for electrical current.  This dehumidifier 
is equipped with a cord having an equipment-grounding conductor and 3 prong grounded plug.  The plug 
must be connected into an outlet that is properly installed and grounded in accordance with all local 
codes and ordinances. 
 
Do not modify the plug provided with the dehumidifier.  If it will not fit the outlet, have a proper outlet 
installed by a qualified electrician. 
 
If the household electrical supply does not meet specifications, or if you are not sure your home has an 
effective ground, have a qualified electrician or your local electrical utility company check it and correct 
any problems. 
 

 

  

 

All wiring must comply with local and national electrical codes and be installed by a 
qualified electrician.  If you have any questions regarding the following instructions, 
contact a qualified electrician. 

 

Check available power supply and resolve any wiring problems 

BEFORE

 installation 

and operation of this unit. 

 

For your safety and protection, this unit is grounded through the power cord plug 
when plugged into a matching wall outlet.  If you are not sure whether the wall outlets 
in your home are properly grounded, please consult a qualified electrician.  

DO NOT 

USE PLUG ADAPTERS OR EXTENSION CORDS.

 

 

The manufacturer’s nameplate is located on the rear with technical data specific to 
this unit. 

 

To avoid the possibility of personal injury always disconnect the power supply to the 
unit, before installing and/or servicing 

    
NOTE: Specifications are subject to change without notice, for further improvements. 

 

 

 

 

3

Summary of Contents for CFM-65

Page 1: ... information or assistance please contact Soleus International 9451 Telstar Ave El Monte CA 91731 Tel 888 876 5387 www soleusair com KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING READ THIS OWNER S MANUAL CAREFULLY BEFORE USE 1 Sales Inquiries 800 934 9194 ...

Page 2: ...erational aspects of this dehumidifier For easy reference please attach a copy of your sales slip receipt to this page along with the following information that is located on the manufacturers nameplate located on the rear panel of the unit Model Number _______________________________________ Serial Number _______________________________________ Date of Purchase ___________________________________...

Page 3: ...kdown grounding will reduce the risk of electrical shock by providing a path of least resistance for electrical current This dehumidifier is equipped with a cord having an equipment grounding conductor and 3 prong grounded plug The plug must be connected into an outlet that is properly installed and grounded in accordance with all local codes and ordinances Do not modify the plug provided with the...

Page 4: ...t please observe the following safety precautions 1 Unplug the power supply cord before cleaning or storage 2 Do not submerge the unit in water or place the unit close to water 3 Do not set the unit close to heat generating devices or near flammable and dangerous materials 4 Never put your fingers or objects into the intake or discharge ducts 5 Do not sit or stand on the unit 6 Discard water that ...

Page 5: ...PRODUCT DIAGRAM FRONT BACK 5 ...

Page 6: ...t desired humidity When using the timer press to select the desired hours Timer On Button When unit is plugged in but powered off press this button for auto start Timer Off Button When the unit is powered on press this button for auto off Swing Button Press the button once for the louver to swing press it again and the louver will return to its vertical position LED Display Water Full Icon When th...

Page 7: ...or high to provide ventilation NOTE 1 In normal operation LED Display shows room humidity press the up or down arrow to see the set humidity 2 When the unit is plugged in but powered off the LED Display shows room humidity OPERATION 1 Power On the Unit Plug the power cord into a properly grounded outlet The LED display shows room humidity Press ON OFF button to turn on the unit 2 Select a Mode Pre...

Page 8: ...t positioned properly the WATER FULL sensor will be activated and the dehumidifier will not operate 4 If the drainage tank is removed while the unit is in operation or immediately after operation has stopped water that is still in the cooling unit may drip out onto the base plate Always wait at least 30 minutes before removing the drainage tank to avoid drips If water has dripped wipe it up 5 Do n...

Page 9: ...the unit is operating as shown in the figure at right MAINTENANCE Cleaning the Dehumidifier To Clean the Body Clean the body of the unit by wiping with a soft damp cloth You may use a mild detergent if necessary Gasoline benzene thinners scouring powder chemically treated dust cloths and detergents may damage the main unit and should not be used To Clean the Air Filter 1 Remove the Air Filter Gras...

Page 10: ...ayed on the LED The tank is full or in a wrong position Discard the water in the drainage tank and then reposition the tank The unit does not operate Is the temperature of the room above 90 F or below 41 F The protection device is activated and the unit cannot be started Is the intake duct or discharge duct obstructed Remove the obstruction from the discharge duct or intake duct The dehumidifying ...

Page 11: ...g provisions in the instructions 3 Damage to the finish of the case or other appearance parts caused by wear 4 Filter 5 Damage caused by repairs or alterations of the dehumidifier by anyone other than authorized by Soleus International Inc 6 Freight and Insurance cost for the warranty service ALL IMPLIED WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO ONE YEAR DURATION...