COMPONENT PARTS LIST & FUNCTIONS.
-
16
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
Solar Collector – Aurora SLAR40 4 x 10, SLAR32 4 x 8, or SLAR24 4 x 6, or SLSG40 4 x 10.
Solar Storage Tank – AO Smith SunX-80 or SunX -120 solar storage tank or equivalent with 4500W Backup Element.
Differential Control – Goldline Differential Control with Adjustable High Limit determines when system is on or off or Steca
0301u or equal. (include Goldline model number)
Circulation Pump – Taco 006BC4 , WIlo Star 8 or G rundfos U P15-18B5 .
Expansion Tank – Appropriately-sized Expansion Tank with 150 PSIG working pressure and 40PSI pre-charge.
Pressure Gauge - ¼” Pressure Gauge for Expansion Tank ranging from 0-60 PSI.
Drain/Charge Valve – 1-5115-017 or 1-5115-020 Boiler Drain used to charge, drain and purge air from the heat
transfer fluid loop.
Charge Valve - 1-5115-017 or 1-5115-020 Boiler Drain used to charge and purge air from the heat transfer fluid loop.
Isolation Ball Valve – 1-5115-023, or 1-5115-027 Ball Valve used in conjunction with #10 and #11 to isolate Circulation Pump
and/or solar loop.
Isolation Ball Valve – 1-5115-023, or 1-5115-027 Ball Valve used in conjunction with #9 to isolate Circulation Pump.
Isolation Ball Valve – 1-5115-023”, or 1-5115-027 Ball Valve used in conjunction with #9 to isolate solar loop.
Check Valve – Watts 600 Check Valve or equal to prevent thermo-siphoning from storage tank through solar collectors.
Pressure Relief Valve – Watts 530C Adjustable Pressure Relief Valve or equal used to relieve excess pressure from heat transfer
fluid loop. If fluid is expelled call your dealer immediately. Ranges of adjustment are 50 to120 psi.
Line Thermometers – 1-5020-028 Line Thermometer w/ temperature range of 50°F to 220°F.
Hot Water Thermometer – 1-5020-028 Line Thermometer w/ temperature range of 50°F to 220°F.
Mixing Valve – Watts 1-5115-015 Mixing Valve tempers temperature of hot feed line to home.
Pressure & Temperature Relief – Watts 100XL-4 P&T Relief Valve located on the solar storage tank opens at 150psi or 210°F.
Rotate the top portion of the pressure relief valve until the 120 PSI line is flush with the pressure relief valve housing.
Tank and Collector Sensors – Goldline SB Tank and Collector Temperature Sensor or equal, but must be type of sensor
compatible with type of #3 Differential Control used.
Cold Water Inlet Valve – 1-5115-034 Gate Valve gives ability to turn off the cold feed to the Solar Storage Tank.
13. Component Parts List & Functions.
INSTALLATION MANUAL SOLENE
®
HOT WATER SYSTEMS
©
2014 UMA Solar
While specific products are mentioned below, there are many components that can be substituted with like or equal products.
For instance there are several different mixing valves or isolation valves that can be utilized, not just the one specifically listed.
Sometimes sweat or threaded connections or varying fitting sizes are dealer preference. All of the components listed below are
available from Solene at 950 Sunshine Lane, Altamonte Springs, FL 32714 (866) 902-0060.
See the schematics on pages 18-23 for the location of the following list of components.