LED INFORMATIONS
INFORMATIONS ON THE STATUS OF THE LR-MB LED
•
Green LED : normal running
•
Green LED flashing : Firmware update in progress
•
Red LED flashing 3 times :
Possible causes :
1/ Loss of Wi-Fi access point (box) or connection not etablished.
Restart your box and the product.
2/ During initialization, the password entered is not correct.
Trick : Enter the password of the box in a « Notes » application on your mobile.
Copy the password with a long press and paste it into the corresponding field.
Repeat the initialization procedure.
3/ During initialization, the product may be too far from the box : bring the
product closer.
•
Red LED flashing 2 times : alarm time : the LR-MB is no longer on time.
If your product is connected to the MySOLEM platform, the time setting
will be automatic. Otherwise, connect to the LR-MB from the application
and check that the message « Synchronization OK » is displayed.
•
•
LED off : the product is not powered.