Installation
and
Operation
Manual
(Rev
A)
PVI
50
‐
100KW
Series
Inverters
DOCR
‐
070233
Page
43
of
92
6.7
Stopping
and
Starting
the
Inverter
WARNING:
Before
conducting
any
maintenance
or
service
on
the
PV
System
the
inverter
disconnect
switches
must
be
set
to
the
“OFF”
position
and
the
absence
of
voltage
must
be
verified
by
qualified
personnel.
Do
not
rely
on
HMI
functions
to
stop
the
inverter
as
a
reset
might
cause
the
inverter
to
start
unexpectedly.
Quick
Stop
and
Start
The
Inverter
can
be
temporarily
stopped
so
that
it
ceases
to
export
power
to
the
grid.
Hold
down
the
ESCAPE
button
for
two
seconds
to
temporarily
stop
the
inverter
if
it
is
running.
Likewise,
hold
down
the
ESCAPE
button
for
two
seconds
to
initiate
inverter
starting
if
it
is
stopped.
Alternatively,
the
inverter
can
be
started
and
temporarily
stopped
through
the
menu.
1.
From
the
Main
Menu
select
the
Set
Inverter
function
and
then
press
the
ENTER
button.
2.
The
Power
Stopped
status
will
be
displayed,
indicating
the
current
status.
3.
Press
the
ENTER
button.
The
display
prompt
will
change
to
Power
Stop
and
the
setting
can
be
modified.
Press
the
DOWN
button
to
change
the
setting
to
Yes
.
4.
Press
the
ENTER
button
to
accept
the
setting.
The
inverter
will
shut
down.
NOTE:
To
start
the
inverter,
change
the
Power
Stop
setting
in
step
3
to
No
instead
of
Yes
.