IMPORTANT
ELECTRICAL INFORMATION
WARNING!
NEVER
use a ground fault circuit interrupt (GFCI) wall outlet with this treadmill. As with
any appliance with a large motor, the GFCI will trip often. Route the power cord away from
any moving part of the treadmill including the elevation mechanism and transport wheels.
NEVER
remove any cover without first disconnecting AC power. If voltage varies by ten
percent (10%) or more, the performance of your treadmill may be affected. Such conditions
are not covered under your warranty. If you suspect the voltage is low, contact your local
power company or a licensed electrician for proper testing.
NEVER
expose this treadmill to rain or moisture. This product is
NOT
designed for use
outdoors, near a pool or spa, or in any other high humidity environment. The maximum
operating temperature specification is 40 degrees c, and humidity is 95%
non-condensing (no water drops forming on surfaces).
Circuit Breakers
: Some circuit breakers used in homes are not rated for high inrush
currents that can occur when a treadmill is first turned on or even during use. If your
treadmill is tripping the house circuit breaker (even though it is the proper current rating)
but the circuit breaker on the treadmill itself does not trip, you will need to replace the
home breaker with a high inrush type. This is not a warranty defect.This is a condition
we as a manufacture have no ability to control. This part is available through most
electrical supply stores. Examples: Grainger part # 1D237, or available online at
www.squared.com
part # QO120HM.
GROUNDING
INSTRUCTIONS
This product must be grounded. If the treadmill should malfunction or breakdown,
grounding provides a path of least resistance for electric current, reducing the risk of
electric shock. This product is equipped with a cord having an equipment-grounding plug.
The plug must be plugged into an appropriate outlet that is properly installed and
grounded in accordance with all local codes and ordinances.
DANGER
- Improper connection of the equipment-grounding conductor can
result in a risk of electric shock. Check with a qualified electrician or serviceman if
you are in doubt as to whether the product is properly grounded. Do not modify the
plug provided with the product if it will not fit the outlet; have a proper outlet
installed by a qualified electrician.
This product is for use on a nominal 110-volt circuit, and has a grounding plug that looks like the plug
illustrated below. A temporary adapter that looks like the adapter illustrated below may be used to
connect this plug to a 2-pole receptacle as shown below if a properly grounded outlet is not available.
The temporary adapter should be used only until a properly grounded outlet, (shown below) can be
installed by a qualified electrician. The
green colored rigid ear-lug, or the like,
extending from the adapter, must be
connected to a permanent ground such
as a properly grounded outlet box cover.
Whenever the adapter is used, it must
be held in place by a metal screw.