Systems and schedulded
maintenance
Solé, S.A. C-243 b, km 2 · 08760 Martorell (Barcelona) ·Tel. +34 93 775 14 00 · www.solediesel.com · [email protected]
23
Operator’s Manual Marine
generators sets
5.3.
General
Solé Diesel offers, for these genset models, a maintenance kit:
Maintenance task. Screw tightening, fastening
For details of tightening torques see Section 9 Torques.
Maintenance task. Valve clearance inspection
The rocker cover must be dismounted to check the valve clearance. This operation must be
carried out when the genset is cold.
Item
Assembly standard
Valve clearance (cold setting)
Inlet
0,3 mm
Exhaus
t
Inspection
1.
Insert the appropriate thickness gauge between the
rocker arm and valve cap to check the clearance.
2.
Loosen the rocker nut (1).
3.
Tighten or loosen adjusting screw (2) to adjust valve
clearance by checking thickness with thickness
gauge (3).
4.
When you have adjusted the thickness, tighten the
rocker nut and recheck the thickness.
With piston nº 1 in the top dead centre of the compression
cycle, adjust the play of the intake and exhaust valves of
cylinder nº 1. Proceed similarly as with the other cylinders. The
position of the BTDC can be confirmed with thea lining signs of
the ditribution or timming cover and the crakshaft pulley.
The adjustment of the valve play must be made after the cylinder head screws are again
tightened. (Strictly comply with the operation sequence indicated in the heading 4.1).
On board spare parts Reference
85 GTC / 100 GTAC / 115 GTC /
120 GTAC DNV
19440110