background image

SolaX Adapter Box

Quick Installation Guide

Packing List

-

 Check that if there is any distortion or impaired during 

transportation.

SolaX Adapter box is matched with a heat pump with dry 
contact function, which can realize heat pump integrated 
photovoltaic inverter energy system management. The inverter 
can control the Adapter box to use solar energy efficiently 
according to the requirements set by the user (grid power, 
battery capacity, time, etc.) Supplying heat pumps is generally 
applicable when there is surplus solar energy and battery 
storage capacity. This part of the energy can be used to heat 
the heat pump within the required temperature range. Please 
read this guide carefully before using.

Mounting

III

Introduction

I

-

 Dismantle the upper cover of the SolaX Adapter Box. 

-

 Pass the expansion screws through box installation channels. 

 Screw

 

the

 

expansion screws.

Quick installation

guide  X1

Expansion tubes X4

Expansion screws X4

Hot water

 Heat pump

8

0

m

m

130mm

112mm

6

2

m

m

Overview

II

φ

6 Drill

 (Depth:

 

30 mm)

IV

6

2

m

m

112mm

-

 

Use the marking cardboard to  x it on the wall and determine the location of the hole.

   

 Drill holes with

φ

6 drill. 

    Depth: at least 30mm.

-

 Tighten the expansion tubes.

Slotted screwdriver

                                                

torque:

 

0.5

±

0.1Nm

                                                              

V

Connection diagram of the external relay for the Smart Grid Ready control of a heat pump.

(For the dry contact K3/K4 wiring on the heat pump, please refer to the heat pump quick installation guide)

K4

K3

K2

K1

1
2

3

4
5

6
7
8

1
2

3

4
5

6
7
8

Inverter

Heat pump

Note:

 

Adapter Box  is usually suitable for heat pumps 

with dry contact function. The connection of the Inverter's 
communication 3/6/7/8pin dry contact and the dry 
contact K3/K4 on the heat pump is controlled.

Wiring

In

ver

ter

Heat pump

K3

K4

01

71mm

N

O

1  

2  

3

Marking cardboard  X1

Note: Please choose a place where the Adapter 
box is not directly exposed to the sun.

Heat pump

Slotted screwdriver

                                                

torque:

 

1.2

±

0.1Nm

                                                              

Reviews: