(6) Export Control: With this function the inverter can control energy exported to
the grid. Whether having this function is based on user’s wishes.
Choose”Enable”in Mode Select means user must install a meter/CT to monitor
energy exported to the grid. There are user value and factory value. The factory value
is default which can not be charged by user. The user value setting by installer must be
less than the factory value and within the range of 0KW to 6KW.
Choose”Disable” means the function will be shut o
ff.
(7) Earth Detect: The default is “Disabled”. If turned on, the inverter will occur an
error
(8) DRM Function: User can choose whether using the DRM function or not.
(9) New Password: Installer can set the new password here.
(10) Reset Errorlog: The user can clear the errorlogs by this function.
(11) Reset Energy: The user can clear the power energy by this function.
(12) Reset Meter : The user can clear the Meter energy by this function.
(13) Line Impedance: User can choose whether using the Line Impedance
function or not. It can reduce the protection of the false voltage caused by the
high impedance.
(14) Self Test(only for CEI 0-21): User can test operating staus of inverter by
choosing ”All Test”. When testing OK, the inverter will restart again and user can
see the result from the “Test Report”.
→
The way to set password:
a) Long press the key (V) to enter the interface, and long press again to modify .
b) Short Press (
Λ
) or (V) to increase or decrease the value you needed.
c) After setting, long press the (V) key to con rm the parameters.
d) Long press (
Λ
) to enter next level.
Operation Method
Troubleshooting
7 Troubleshooting
7.1 Troubleshooting
This section contains information and procedures for solving possible problems
with X1 series inverters, and provides you with troubleshooting tips to identify
and solve most problems that could occur with the X1 series inverters.
This section will help you narrow down the source of any problems you may
encounter. Please read the following troubleshooting steps.
Check warnings or fault messages on System Control Panel or Fault codes on the
inverter information panel. If a message is displayed, record it before doing
anything further.
Attempt the solution indicated in
troubleshooting list
s.
●
If your inverter's information panel is not displaying a Fault light, check the
following list to make sure that the present state of the installation allows proper
operation of the unit.
— Is the inverter located in a clean, dry, adequately ventilated place?
— Have the DC input breakers been opened?
— Are the cables adequately sized and short enough?
— Are the input and output connections and wiring in good condition?
— Are the con gurations settings correct for your particular installation?
— Are the display panel and the communications cable properly
connected and undamaged?
Contact SolaX Customer Service for further assistance. Please be prepared to
describe details of your system installation and provide model and serial number
of the unit.
Enable
>
Mode select
>User Value
4000
W
→