3  Installation of the large display panel

 Important Notice:  

Improper installation of the large display panel can cause 
severe personal injury or damage to property.

The large display panel is intended for wall installation.

The large display panel is suitable only for indoor use. 

 Important Notice:  

Do not install the large display panel above passageways!

Gap between holes 746 mm

G

ap 

be

tw

ee

ho

le

s 5

46 

m

m

 Caution:  

Do not tighten screws too firmly! Glass breakage is not covered under 
warranty!

The stainless steel washer must be positioned 
directly on the spacer. The washer sits some-
what loosely.

Summary of Contents for Suntrol STD800LED

Page 1: ...STD800LED Large display panel for photovoltaic systems Installation instructions SolarWorld And EveryDay is a SunDay www solarworld de ...

Page 2: ...ction to a Sunny Boy Control Standard Plus using RS 485 10 4 2 1 Connection information 10 4 2 2 Connection diagram 11 4 3 Connection to a Sunny Boy Control Light Standard Plus using RS 232 12 4 3 1 Connection information 12 4 3 2 Connection diagram 13 4 4 Connection to a SolarWorld Suntrol using RS 485 13 4 4 1 Connection information 14 4 4 2 Connection diagram 14 5 Configuration of the large dis...

Page 3: ...ce or to keep a close watch on display values Please read these installation instructions carefully all the way through before using the large display panel We hope your presentations will find much success Our efforts in pursuit of complete customer satisfaction do not end with the sale of our products We are also there for you during their use If you have any questions comments or suggestions pl...

Page 4: ...espective owners Use only the original power supply Disconnect power supply from power grid after use The power supply is not for use in wet conditions These instructions are an important component of the product They contain important information on the operation and handling of the product Please keep this in mind particularly if you transfer the display to a third party Proper use of the Suntro...

Page 5: ...ded for wall installation The large display panel is suitable only for indoor use Important Notice Do not install the large display panel above passageways Gap between holes 746 mm Gap between holes 546 mm Caution Do not tighten screws too firmly Glass breakage is not covered under warranty The stainless steel washer must be positioned directly on the spacer The washer sits some what loosely ...

Page 6: ... panel has various inputs and interfaces The most common connec tion options for the large display panel are described instructions Please use only the connection information according to the required input Connecting terminal assignment A cable comes out of the back of the large display panel and is assigned as follows Taster für Konfiguration Connection according to configuration data 1 12 V DC ...

Page 7: ...panel The low voltage output free cable ends of the power supply is connected to terminal 1 pin 1 and pin 2 of the large display panel Pay attention to the polarity here If the power supply cables need to be lengthened the extension wires should have about a 0 75 mm2 cross section After the installation to the large display panel is complete the power supply is plugged into a 230 V AC outlet ...

Page 8: ...ted with correct polarity to terminals 1 and 2 If the power supply cable needs to be lengthened the wires should have about a 0 75 mm2 cross section Please note that the power supply must only be used in dry places The pulsed output floating make contact of the current meter is connected to terminals 7 and 8 of the large display panel A shielded cable must be used to connect to the current meter T...

Page 9: ...tzlich muss die Leitungsverlegung fern von starken Stromverbrauchern sowie deren Zu und Ableitungen erfolgen Bei Leitungslängen über 100 m bis ca 600 m vom Stromzähler bis zur Großanzeige kann ein separates Signal Verstärker Set verwendet werden Dies ist auf Anfrage erhältlich 2 2 Anschluss an einen Sunny Boy Control Standard Plus über RS 485 1 2 7 8 Netzteil Schirm Großanzeige Stromzähler Beispie...

Page 10: ...d supply is connected with correct polarity to terminals 1 and 2 If the power supply cable needs to be lengthened the wires should have about a 0 75 mm2 cross section Please note that the power supply must only be used in dry places The RS 485 output COM 2 or 9 of the Sunny Boy Control is connected to terminals 3 and 10 A shielded cable must be used to connect to the Sunny Boy Control The size of ...

Page 11: ...r Schirm wird nur an 0V Klemme 2 der Großanzeige angeschlossen und bleibt auf der Seite des Sunny Boy Control offen 2 2 2 Anschluss Schema 2 3 Anschluss an einen Sunny Boy Control Light Standard Plus über RS 232 Die RS 232 Schnittstelle ist zum Anschluss eines entsprechend ausgestatteten Sunny Boy Control über eine RS 232 Verbindung für Leitungslängen bis max 15 m vorgesehen Netzteil Schirm Sunny ...

Page 12: ...pply is connected with correct polarity to terminals 1 and 2 If the power supply cable needs to be lengthened the wires should have about a 0 75 mm2 cross section Please note that the power supply must only be used in dry places The RS 232 output COM 2 or 3 of the Sunny Boy Control is connected to terminals 3 and 4 A shielded cable must be used to connect to the Sunny Boy Control The size of the c...

Page 13: ...ol COM2 3 RS 232 Power supply Shield max 15 meters 1 1 6 5 9 2 3 Large display panel 4 4 Connection to a SolarWorld Suntrol using RS 485 The RS 485 interface is intended to connect to a SolarWorld Suntrol datalogger using an RS 485 connection for total cable lengths up to 1000 m Important Notice The baud rate set in the large display panel must agree with the baud rate of the inverter This must be...

Page 14: ...the large display panel terminal 9 is connected to RS 485 pin 1 of the Suntrol Data of the large display panel terminal 10 is connected to RS 485 pin 4 of the Suntrol With the STL800 RS 485 A or B can be used except Fronius see above The shield is connected only to 0V terminal 2 of the large display panel and remains open on the Suntrol side 4 4 2 Connection diagram Power supply Shield Large displ...

Page 15: ...is a current meter with pulsed output Starting value for total output kWh Pulse rate pulses kWh The settings are made using the button between terminals 6 and 7 How long the button is pressed determines the result Duration Result Note Short press 1 second The value of the number to be changed is in creased by 1 The value is increased when the button is released Long press 1 5 seconds The number pl...

Page 16: ...After 9 the number goes back to 0 If you accidentally miss the desired num ber you can get back to it by pressing the button briefly several more times Long press The selected data source is saved Important Hold the button down until the display runs a segment test or StArt appears in the top field The data sources in the second field are numbered as follows 0 Current meter with pulsed output 1 Su...

Page 17: ...an get back to it by pressing the button briefly several more times Long press The decimal point moves one place to the left Exception the far right place the decimal point does not appear here Important Hold the button down until the decimal point moves to the next place It must go through all 6 places for the value to be stored f Once all of the places in the starting value have been changed as ...

Page 18: ...6 Factory settings Terminal Standard Pulse 1000 I kWh Top display value Current power in watts Middle display value Total energy in kWh Bottom display value CO2 savings in kg Factor CO2 savings 0 70 kg kWh ...

Page 19: ...ption 15 to 50 C Storage and transport temperature 20 to 60 C Supported data sources depending on configura tion data source must be indicated with order Pulse generator floating make contact SMA Sunny Boy Control Standard Light and Plus Suntrol 200 400 and 800 various other systems on request Inputs interfaces Pulse for floating make contact minimum pulse length 2 ms RS 232 RS 485 Power supply Ex...

Page 20: ...SolarWorld AG Martin Luther King Str 24 53175 Bonn Germany Phone 49 228 55920 0 Fax 49 228 55920 99 service solarworld de www solarworld de SolarWorld And EveryDay is a SunDay www solarworld de ...

Reviews: