Summary of Contents for SWF850

Page 1: ...User Manual Enerwise Solutions Ltd EMAIL sales enerwise asia Copyright 2013 Enerwise Solutions Ltd All rights reserved...

Page 2: ...uential damages under any circumstances The exclusion of implied warranties may not apply in all cases under some statutes and thus the above exclusion may not apply Specifications are subject to chan...

Page 3: ...t AI 8 2 4 4 Connecting to the Digital Input DI 10 2 4 5 Connecting to an External Revenue Meter 11 2 4 6 Connecting to the Digital Output DO 12 2 4 7 Connecting the Ethernet 13 2 4 8 Connecting the C...

Page 4: ...port 39 4 9 7 Monthly Report 39 4 9 8 Annual Report 39 4 10 Project Details 39 4 11 DEMO Page 39 4 12 Setting 41 4 12 1 Global Setting 42 4 12 2 SWF Setting 51 4 12 3 Database 54 4 12 4 Driver 55 4 12...

Page 5: ...e LCD Display and keys operation Linux Embedded WEB server with built in WEB not requiring Cloud service Configurable Settings for connect to Cloud service Alarms sent via Email to plant operators let...

Page 6: ...ipment status they also can be used as input of energy pulse from electricity meter 2 2 Installation Safety Pre Cautions Note1 Damage due to in correctly connected cables All interfaces of SWF850 have...

Page 7: ...24V AI6 GND AI5 GND 24VDC SolarWise RJ45 CONNECTOR RJ45 CONNECTOR RJ45 CONNECTOR RJ45 CONNECTOR Ethernet2 164mm 39 6mm 39 6mm 10 8mm 10 8mm 63 2mm 11 7mm 18mm 16mm 60mm 2 4 Installation The following...

Page 8: ...pe Terminal Wire Size AWG 12 30 length of exposed copper 6 7mm Signal Type Direct Voltage Signal Range 18 28 V Powermax 5W 2 4 3 Connecting the Analog Input AI SWF850 has a total of 6 analog inputs AI...

Page 9: ...e 100 Accuracy 0 5 Full Scale The connection method between AI1 AI4 and two wire sensors is described as below SWF850 24VAI424V 24VAI1 AI3 AI2 24V 24VDC 2 Wire Type Sensor The connection method betwee...

Page 10: ...4 Wire Type Sensor Sensor Power Input AI6 GND GND AI5 2 4 4 Connecting to the Digital Input DI SWF850 has a total of 6 digital inputs DI1 to DI6 DI_Vout is the built in internal excitation voltage of...

Page 11: ...hese pulses are called Kt pulses which usually one pulse represents a certain amount of kWh measured in the meter Hence by collecting such pulse from the meter will allow SWF850 logger to cumulate the...

Page 12: ...led or do not have pulses available it is necessary to goto the software setup to link the total energy kWh data to the inverter energy data instead of a real meter For this procedure please goto sect...

Page 13: ...s of the interfaces are shown as follows Max Wire Length 1000 m Max Connected Devices 32 Devices Supported Baud Rates 4800 38400bps Isolation Optically Isolated Isolation Capability 1000VAC 1min 2 4 9...

Page 14: ...be used to change the value of parameters Enter For enter the sub menu or for confirm the current modification parameter values Esc For back to the previous menu or exit the parameters setting status...

Page 15: ...n INV1 Total power ABn AB1 Total Current Total power Volt Generation Month kWh Year kWh Daily kWh Total kWh Yesterday Today Last This Last This Total energy Total energy Status Analog Input Export ene...

Page 16: ...t1 Ethnet2 DHCP Set DHCP server Enable Disable IP Set fixed IP address when DHCP Disable Gateway Set gateway address when DHCP Disable Subnet mask Set fixed subnet mask when DHCP Disable Settting Ethe...

Page 17: ...tup 1 Cloud server IP Set the IP address of Cloud server Port Set the IP port of cloud server 2 Cloud enables Enable or Disable the function to connect cloud server before this setting users should ge...

Page 18: ...Analog measurements have been calibrated with right input source before left factory user do not need to recalibrate it in the general case Maintenance Password Display setup Contrast Date Time Date...

Page 19: ...SOE Clear Data and Reset Setting Note Resetting to the factory settings affects the following functions 1 LAN1 is set to DHCP Enable 2 LAN2 is set to fixed IP address DHCP Disable IP 192 168 1 100 Sub...

Page 20: ...r the client browsers currently support the browser version is as follows Browser Name Version Range Platform IE 9 0 10 0 Win7 and above Google Chrome 29 0 Win XP Opera 12 12 Win XP Firefox 24 Win XP...

Page 21: ...the users may know about the basic functions of the system which include Summary AC Network Inverter Strings Report Project Details and Setting 4 4 Title On the top of web page there are two lines ti...

Page 22: ...roject Details Then on the lower left is the total AC power graph The graph shows the values of AC Total power of inverter Irradiation Temperature at every 10 minutes The messages for every data dot w...

Page 23: ...lease goto section 4 12 6 1 4 5 2 Power All the power generated by critical equipments can be show on the power view graph Then on the right of this page there is the graph which could show the power...

Page 24: ...based on the history power data It is a very good reference used to reflect the now generation performance by the equipments comparing with the history generation The function for expected power range...

Page 25: ...onth 4 5 4 Real Time This page displays the real time information read from the inverter and arraybox There are three portions in this page On the right hand is in the device list there are three leve...

Page 26: ...Solarwise SWF850 QuickStart Troubleshooting Manual 73 73 SolarWise PV Farm Management System SWF 850 User Manual...