electRicAl cOnnectiOn AnD gROunDing

SOLARWATT solar modules are equipped at the factory with 
high-quality solar cables and reverse-polarity protected, 
shock proof plug connectors. The connection of the string line 
has to be done with identical connectors manufacture and 
type as to the module connecting cable. To be able to ensure 
this the module connector at the beginning and the end of 
the string may be removed and replaced (More information in 
the download area at www.solarwatt.net). The allowed cross-
section and outer-diameter of the cable and instruction of 
the manufacturer have to comply. The following table shows 
matching cablesets, plugs, cables and installation accesso-
ries. When connecting the modules, ensure that the plugs en-
gage with an audible click. The common bending radii of at 
least 5 times the outer cable diameter must be complied with. 
It is recommended to lay the cable firmly so that they are not 
subjected to mechanical loads. The cable and connector must 
not exposed to moisture and will not rest on the ground or 
floor. To ensure safety and compliance with the technical data 
of the products, only original tools of the manufacturer may 
be used in the self-assembly of solar cables.
Connection of modules in series is only permitted up to the 
maximum system voltage as listed in applicable data sheet. 
The maximum number of solar modules installed parallel 
without string fuse is two. Please comply with the value spec-
ified in the data sheet for reverse current feed and only use 
standardized photovoltaic cables (recommendation: at least 
4 mm² cable cross-section). The solar modules correspond to 
application class A and can therefore be operated in systems 
with dangerous DC voltages (larger than 120 VDC in accor-

dance with IEC 61730). Solar modules in this application class 
can be used in systems with unrestricted access, the relevant 
regulations must be complied with. SOLARWATT solar mod-
ules qualified within this application class in accordance with 
IEC 61730 fulfill the requirements of protection rating II with 
correct electrical installation.

Module schematic, front view

Connection lines

String connector

Junction box with bypass diodes

Cell connector

Solar cells

 WARning

Solar modules generate electrical energy on the front side during incidence of light. 
A system with multiple solar modules can generate life-threatening voltages and 
electrical currents. Do not touch the electrical connections or cable ends while the solar 
module is exposed to light.

Subject to change | © 2016 SOLARWATT GmbH | AZ-TM-PMS-0973 | Rev 008 | Status: 11/2016

14

Summary of Contents for Vision 60P style

Page 1: ...ION INSTRUCTIONS for framed glass Foil solar modules EU Standards EUROCODE 1 EN 1991 1 Actions on structures EN 13501 Fire behavior of building materials and building component EN 60728 11 Setting up...

Page 2: ...ent which go above and beyond the current valid standards and enable us to optimize our products continually If treated correctly your SOLARWATT solar modules will offer you several decades of service...

Page 3: ...energy yield Comply with the minimum distance of 5 mm between the solar modules to allow the material to expand without tension SOLARWATT solar modules fulfill all the requirements of the extended tes...

Page 4: ...oad to the solar mod ule for the installation method is 2 400 N m Fastening on short sides The maximum pressure load to the solar mod ule for the installation method is 2 400 N m Vertical installation...

Page 5: ...0 N m Horizontal installation inseRtiOn sYsteM Fixed in place by inserting in a supporting frame 3 Vertical installation The maximum pressure load to the solar module for the installation method is 2...

Page 6: ...assembly of solar cables Connection of modules in series is only permitted up to the maximum system voltage as listed in applicable data sheet The maximum number of solar modules installed parallel wi...

Page 7: ...25 and the open circuit voltage UOC should be multiplied by a factor of up to 1 25 based on the lowest ex pected ambient temperature for the given installation loca tion to determine the rated voltage...

Page 8: ...lso be used in the recommended dose Do not use aggressive cleaning agents or metal objects as they can be particularly damaging to the hardened glass surface The electric cables should where accessibl...

Reviews: