12 mySOLARFOCUS app
15.1 Required activities - overview
The implementation responsibility of the maintenance
activities is defined according to type and extent (sys-
tem operator
SO
or qualified personnel
QP
).
Activity
Interval
AB QP
Empty ash container
upon noti-
fication
message
[1]
X
Check system pressure
monthly
X
Clean flue gas pipe
six-monthly
[2]
X
Check safety valve
yearly
X
Maintenance by qualified per-
sonnel
yearly
X
Perform emissions mea-
surement
as per
regional
regulations
X
[1] You can use the
E-mail message
function to be informed
about an upcoming emptying of the ash container (see
Alarm
selection
button)
[2] Indication is valid for average consumption values; adjust the
interval according to your own requirements.
15.1.1 Empty ash container
Empty the ash container when the message on the
boiler control display appears.
Information on the necessity of emptying the ash con-
tainer:
Abb. 2-57
►
Wait until the burner switches off (the burner still
fulfils its heating requests, i.e. this can take lon-
ger).
►
Turn lever
1
to the right until the stop and remove
the ash container towards the front.
Abb. 2-58
►
To avoid ash escaping, loosen the knurled nut
1
and move the slide downwards.
►
Open the 4 turnbuckles
2
and remove the lid
3
upwards.
Abb. 2-59
►
Empty the ash container.
DANGER
- risk of fire due to hot ash self-igni-
ting. Only store removed ash in metal con-
tainers with a lid.
►
After replacing the emptied ash container, lock
the bar again by pulling it forwards.
►
Confirm the information message on the display
with OK
1
Operation manual
maximus L
39