3. Drill the holes and mount the device using screws and nuts. Fasten the unit to the wall.
4. Release the three internal screws at the bottom of the device, and remove the cable bracket.
5. Connect
the
load
wires
to
the
terminal
blocks
(see
).
w
Figure 2: AC Switch connections
6. Place the cable bracket over the cables and fasten using the screws.
7. Attach the cover to the device and fasten the screws.
8. For configuration and troubleshooting, refer to
http://www.solaredge.com/sites/default/files/se-device-control-switch-installation-guide.pdf
Specifications
ELECTRICAL SERVICE
SEHAZB-SWITCH-MTR
Units
Operating Voltage Range - Line to Neutral
90 - 250
Vac
AC Frequency
50/60
Hz
Maximum Active Power Measurement
3
kW
Maximum Load Current
13
A
COMMUNICATION
Supported Communication Protocol
ZigBee Home Automation
Nominal Transmit Power
3
dBm
Operating Frequency Range
2.4 - 2.5
GHz
Outdoor (LOS) Range
100
m
50
m
Indoor
Range
1
STANDARD
COMPLIANCE
Radio
ETSI EN 300 328 V 1.8.1, ETSI EN 301 489-1, ETSI EN 301 489-17
Safety
EN 60335-1, EN 60335-2-30, EN 50371
Immunity
EN 55014-2
Emissions
EN 55014-1, EN 61000-3-2, EN 61000-3-3
INSTALLATION SPECIFICATIONS
Operating Temperature Range
0 to +50
°C
Protection Rating
IP30
Dimensions (H x W x D)
110 x 70 x 25
mm
Mounting Type
Wall mount
1
Approximate values. May differ depending on specific installation conditions.
AC
Switch
Quick
Installation
Guide
MAN-01-00288-1.
1
2
AC Switch with Meter Quick Installation Guide