NOTE
This data is accumulated according to an internal real-time clock.
Telemetry Status
This screen displays the last power optimizer telemetry received. The display changes as
each power optimizer sends its telemetry.
In order to verify proper installation, the installer may view the Telemetry window for
some time in order to observe the power optimizers' report process.
M o d u l e : 1 0 2 8 8 0 6 3 1 B
E n e r g y [ W h ] : 5 6 . 7
V d c _ O [ V ] : 4 0 . 0
V d c _ I [ V ] : 3 8 . 3
I _ i n [ A ] : 7 . 8
T e m p [ C ] : 2 8 . 0
Module: Power optimizer serial number
Energy: power optimizer energy
Vdc_O: Power optimizer output voltage
Vdc_I: Power optimizer input voltage (module voltage)
I_in
: Power optimizer input current
Temp
: Power optimizer temperature
ID Status
This screen displays the inverter software version and the country to which the inverter
is configured.
I D : # # # # # # # # # #
D S P 1 / 2 : 1 . 0 2 1 0 / 1 . 0 0 3 4
C P U : 0 0 0 3 . 1 9 x x
C o u n t r y : E S P
ID: The inverter ID.
DSP 1/2: The DSP digital control board firmware version
CPU: The communication board firmware version
Country: the current country setting