165
Ingeteam
45 Ingeteam
45.1
INGECON® SUN 1Play TL M
Termination
Addressing
Interface
Jumper P3
Yes
RS485
Supported models:
•
INGECON® SUN 1Play 2.5TL M
•
INGECON® SUN 1Play 3TL M
•
INGECON® SUN 1Play 3.3TL M
•
INGECON® SUN 1Play 3.68TL M
•
INGECON® SUN 1Play 4.6TL M
•
INGECON® SUN 1Play 5TL M
•
INGECON® SUN 1Play 6TL M
Note:
The SUN 1Play TL M models have 1 phase and 2 MPP tracker.
Overview:
•
Interface not integrated; Retrofit RS485 interface card.
•
3-pin wiring.
•
Communication address must be allocated.
•
Installation steps:
•
Switch off the inverters and Solar-Log™.
•
Install the RS485 interface in the inverter.
•
Connect inverters to the Solar-Log™.
•
Connect the inverters to each other.
•
Allocate communication address.
Installing the RS485 interface
Procedure
►
Install the RS485 interface in the inverter in accordance with the interface card installation instructions.
Connect inverters to the Solar-Log™
The wiring is done using a
•
self-made, shielded 3 wire data cable and terminal block connector.
Summary of Contents for Solar-Log
Page 1: ...1 Components Connection Manual V 4 2 3 Solar Log EN ...
Page 20: ...20 01 Inverter ...
Page 398: ...398 Appendix 113Appendix 113 1 SMA mixed wiring Fig SMA mixed wiring ...
Page 402: ...402 02 Meter ...
Page 444: ...444 03 Battery Systems ...
Page 456: ...456 sonnen Note Only one battery system can be connected to a Solar Log device ...
Page 463: ...463 04 Heating rods ...
Page 470: ...470 05 Heating pumps ...
Page 478: ...478 06 Sensors ...
Page 488: ...488 07 Pyranometer ...
Page 495: ...495 08 Smart Plug components ...
Page 502: ...502 09 Power Charging Stations ...