What is an Air Solar Heater 

This  SIS  air  solar  heater 

uses  the  sun’s 

solar  energy  to  heat  air  through  a  window  in 
the  home,  apartment,  cottage,  boat,  RV,  and 
circulate  this  heated  air  in  the  room.  This  is 
not a solar PV panel or solar water heater. 

The  heater  is  hung  or  placed  in  a  south 

facing  closed  window  inside  the  room  or 
space to be heated. 

 

 

This SIS model  air solar heater  heats  air. 

It is like an electric room convection air space 
heater except it is operated by the s

un’s solar 

energy. Hang or set it in a sun facing window, 
or side-ways, or even upside down, and it will 
maintain  heat  in  a  large  room  or  area  in  the 
home. The heating capacity is equivalent to a 
150 to 500 watt electric heater, depending on 
the daytime sun and cloud cover.  

The  model  air  solar  heater  is  also 

transparent  and  will  still  let  most  of  the 
window sunlight into the room.  

Sunlight  and  a  PV  panel  also  operate  a 

fan on the heater. The fan draws the room air 
into the  heater  and then  pulls  the  air through 
metal  solar  energy  collectors  heated  by  the 
sun.  The solar heated air is recirculated back 
into the room. The fan has a speed control so 
the  air  exchange  in  the  room  can  be  set, 
usually  to  1  to  1-1/2  hours,  at  up  to  75  cubic 
feet per minute. 

 
Patented technology and 
international patents pending. 
 
 

 
 
IMPORTANT 

This  SIS  solar  air 

heater  is  designed  for 
interior  installation  behind 
a  single  pane  window  for 
best 

efficiency.  Double 

pane,  low-E,  argon,  and 
triple pane  will reduce this 
efficiency to less than 40% 
to 65%. .  

The  SIS  Solar  Air 

Heater,  mounted  inside 
the  room, 

behind 

the 

window  glass,  reverses 
this  heat  loss,  collects  the  solar  heat  coming 
through  the  glass,  and  heats  the  air  in  the 
room. Ordinary single  glazing works best with 
an interior Air Solar Heater.  

SIS has a range of exterior mount models 

that  are  not  affected 
by  glass  obstruction 
and  are  capable  of 
heating 

an 

entire 

house. 

For 

more 

information

 

call 1 855 

535  2056  or  email  us 
at

  

[email protected]

 

 

 

Also the perfect answer to 

heating sheds, garages, 

cottages, and stored boats and 

RV’s where there is limited or 

no electricity. 

Solar-Infra Systems International Ltd 

209-19138 26

th

 Avenue, Surrey, BC, V3S 3V7 

Canada.  Toll Free 1-855-535-2056                

T-604-535-2056 F-604-535-0681               

www.solarinfrasystems.com 

OPERATING INSTRUCTIONS 

SOLAR THERMAL AIR HEATER 

 Consumer Model SIS C25M 1848 

Issue 1/6/2013e 

The SIS Air Solar Heater Installation 

1. 

Hang,  or  set  on  the  sill,  in  a  south  facing  window.  The  window  should  be 
ordinary single glazing.  

Turn the speed control knob to maximum. 

2. 

Large glass areas, such as solariums, can have too much heat loss through the 
glass to the air outside, for this size of SIS air solar heater. It may require more 
than 

one 

heater 

or 

larger 

model. 

Please 

contact 

us 

at 

[email protected]

 and we will help you size the solar heating.  

3. 

The  Solar  Heater  can  be  mounted  between  the  window  and  a  venetian  blind. 
Make sure the blind is open enough to allow fan recirculation into the room.  

4. 

Use  the  fan  speed  control  to  adjust  the  room  temperature.  The  slower  the  air 
flow,  the  higher  the  outlet  temperature,  because  of  the  increased  air  retention 
time  in  the  heater.  Rooms  and  home  areas  usually  are  planned  for  1  to  2  air 
changes every three hours. Turn the knob clockwise to increase the air flow.  

5. 

The fan capacity is 75 cubic feet of air per minute. Divide this into the volume of 
the room or heated area and this will show the number of air changes per hour. 

6. 

For example:   
Air changes = Room 20ft x 15ft x 10 ft high = 3000 cubic feet volume. 
 
Air Changes=   3000 cubic ft               =      .66 air changes per hour 

                75 cu ft/min x 60 min/hr        (~2 air changes every 3 hours) 

 

7. 

Cloudy,  low  sunlight,  or  rain  conditions  may  not  produce  enough  Photovoltaic 
Panel  energy  on  the  front  of  the  heater  to  operate  the  fan,  even  though  there 
may  be  enough  solar  energy  for  the  heater  to  add  3-4  degrees  to  the  room 
temperature.  Use  the  AC  adapter  to  operate  the  fan  from  household  power.  (a 
timer can schedule the fan for day use only). The cost is minimal. 

8. 

For  cottages  and  homes  without  power,  an  optional  large  PV  panel  will  be 
available for increased sensitivity for low sunlight conditions. 

9. 

WHAT  IS  YOUR  PAYBACK:

  We  use  a  NASA/Government  program  that 

calculates the energy savings and heating output in most locations in the world. 
Email  your  location,  home  area,  electricity  cost  per  kWh,  heating  fuel  and  unit 
cost,  and  we  will send  you  the  time  payback  estimate  on the savings in  energy 
by using an air solar heater or fill in form at www.solarinfrasystems.com  
 

Don’t forget to fill out the 

Warranty Card and the Solar 

Energy Payback Estimator 

 

Radiative Conductive

Total

Compared to

Heat

Heat

Heat

Single Pane

Indoor

Window Construction

Loss

Loss

Loss

Heat Loss

Glass

(Btu/hr/ft2) (Btu/hr/ft2) (Btu/hr/ft2)

Reduction

Temp(°F)

Single Pane

Clear

35

21

56

----

26

Double-Pane

Clear

21

13

34

39%

44

Double-Pane

Low-E

5

15

20

41%

54

Double-Pane

Low-E Argon

2

16

18

47%

56

Triple-Pane

Low-E

2

11

13

62%

59

Triple-Pane

Low-E Argon

1

11

12

65%

60

Reviews: