23
PARAMETER CHECKING AND ADUSTMENT
Parameter list
Some parameters can be checked and adjusted by the controller. Below is the parameter list.
Parameter
No.
Description
Range
Default
Remarks
0
Tank water setting temp.
10 ~ 70°C
55°C
Adjustable
1
Inlet/Outlet water temp difference
2 ~ 15°C
5°C
Adjustable
2
E-heater starting up tank water temp
10 ~ 90°C
55°C
Adjustable
3
E-heater delay time
10 ~ 90 min
30 min
t * 5 min
4
Week disinfection temperature
50 ~ 70°C
70°C
Adjustable
5
High temp disinfection time
0 ~ 90 min
30 min
Adjustable
6
Defrosting period
30~90 min
45 min
Adjustable
7
Defrosting entry coil temp.
-30 ~ 0°C
-7°C
Adjustable
8
Defrosting exit coil temp.
2 ~ 30°C
13°C
Adjustable
9
Max defrosting cycle period
1 ~ 12 min
8 min
Adjustable
10
Electronic expansion valve adjustment
0/1
1
Adjustable
(0-manual
,
1-auto)
11
Target over-heat degree
-20 ~ 20°C
5°C
Adjustable
12
Steps of manually adjusting the electronic
expansion valve
10 ~ 50 Step
35 step
Adjustable
13
High Temp. Disinfection Start Time
0 ~ 23 Hour
23 Hour
Once a week by set
time with power on
A
Inlet water temp.
-9 ~ 99°C
Actual testing value. Error code PP1
will be shown in case of a malfunction
B
Outlet water temp.
-9 ~ 99°C
Actual testing value. Error code PP2
will be shown in case of a malfunction
C
Evaporator coil temp.
-9 ~ 99°C
Actual testing value. Error code PP3
will be shown in case of a malfunction
D
Return gas temp.
-9 ~ 99°C
Actual testing value. Error code PP4
will be shown in case of a malfunction
E
Ambient temp.
-9 ~ 99°C
Actual testing value. Error code PP5
will be shown in case of a malfunction
F
Electronic expansion valve step
0 ~ 50 step
N*10 step
EN
Summary of Contents for PST-250 Aero Termo
Page 1: ...Domestic Hot Water Heat Pump Operation and Installation Manual ENGLISH 02 07 2012...
Page 8: ...8 OVERVIEW OF THE UNIT Parts and descriptions...
Page 10: ...10 Water tank dimensions...
Page 26: ......
Page 27: ...27 WIRING DIAGRAM Please refer to the wiring diagram on the electric box EN...
Page 31: ...31 NOTES EN...