background image

… … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … … …
Please note:
1. the output will cut off once there is over load or short circuit. Press the power switch, the

controller will resume to work after 30 seconds.

2.

After over discharged, the controller will resume to work when the battery is charged to 13.1V.

(for 12V system only, for 24v, use 2X)

3

After over discharged, the controller will resume to work while you press the power switch, note the battery

voltage needs to be over 12.5V.

To correct problem

1. Check wires
2. Reduce amps if needed
3. Reset controller

Disconnect b

Reconnect b

RATINGS (12V or 12/24V auto work)

EPHC-5

5 Amps for Solar and Load

EPHC-10

10 Amps for Solar and Load

NOTES: For use with solar panels only

TECHNICAL INFORMATION

Regulations point

14.4 Volts

Low voltage Disconnect

11.1V Volts

Low voltage Reconnect

13.1 Volts

Note: all is for 12V system only, use 2x for 24 Volt system

Microcontroller digital accuracy

Type of Charging

Series PWM & stat of charge(SOC)

4 Stages: equalization, PWM, Boost and Float,
temperature compensated charging

Electronic protections

Short circuit and over current-solar and load

Reverse polarity-solar, load, battery
Reverse current at night
Limits high voltage to protect loads
Lighting protection

Tropicalization

Conformal coated printed circuit board

Terminals

For wire sizes to

6mm

²

Weights

160g

Self-consumption

6mA maximum

Temperature

-35

to 55

Enclosure

IP22

Warranty

1 years

Compliance

CE

Reviews: