December 2020
|
Solar Stik
®
, Inc.
32
|
Operator and Maintenance Manual for the PRO-Verter S 3000
PRELIMINARY
• AC Input Power Cable:
Connect AC power output port on the generator to the “AC Input” port
on the right-hand side of the PRO-Verter S 3000.
• Grid Power Cable:
Connect AC power from the grid to the “AC Input” port on the right-hand side
of the PRO-Verter S 3000. A custom cable may be required, depending on the grid power outlet.
b How to Connect PRO-Verter to AC Power Source(s)
Figure 12. PRO-Verter(s) to AC power input connections
May be paralleled
May be paralleled
Compatible Generator Options
The PRO-Verter S 3000 can remotely start/stop TQGs that have been modified with a Solar Stik
Remote-start Enabling Kit (RsEK) and the 1 kW and 2 kW Man Portable Generators (MPGs) (Figure
13).
Figure 13. Compatible generator options
MEP-802A
5 kW TQG
MEP-831A
3 kW TQG
Ranger
2 kW MPG
Defender
1 kW MPG
Note:
The TQGs above must have a Solar Stik RsEK installed to be compatible with the PRO-
Verter S 3000.
Tactical Quiet Generators (TQG)
Man Portable Generators (MPG)
Note:
The PRO-Verter
automacitally prioritizes grid
power over genset when
both AC power sources are
connected simultaneously
PRO-Verter S 3000
right-side
grid power
120 VAC, 60 Hz
AND /OR
fuel-powered
generator 1-5 kW