Operator and Maintenance Manual for the PDM 3000

Return Material Authorization

If Customer believes a Product is defective, a Return Material Authorization (RMA) number must be 
obtained from Solar Stik prior to shipment of such Product back to Solar Stik. The RMA number 
must appear on all packages returned to Solar Stik and be referred to in all related correspondence. 
Return shipment of the Product for which damages are claimed shall be at Customer’s expense, 
and such Products shall not be returned, repaired, or discarded without Solar Stik’s written 
consent. Returned Products will be subject to inspection and final determination as to whether or 
not any adjustment is due. If the inspection shows the warranty for the Product is breached, the 
provision of WARRANTY (below) will apply. Solar Stik advises that Customer order recommended 
spares and maintenance parts, especially for critical OCONUS operations. Otherwise Customer 
may experience system downtime during the return and inspection of nonworking components.

Warranty

1  

Solar Stik warrants, unless otherwise agreed to between buyer and seller (Solar Stik, Inc.), for 
a period of one (1) year from Solar Stik’s delivery of such Products, the Products shall be free 
from defects in materials and workmanship and shall conform to the contractual specifications 
or to specification sheet of the Product. This warranty does not cover defects or failure caused 
by improper handling, storage, maintenance, or repair or by any modification, misconnection, 
abuse, abnormal use of such Products (inter alia, overloading or overcharging) or use not 
complying with Solar Stik’s user manual provisions if any. 

2  

Warranty claims must be made to Solar Stik immediately after discovering the defect and within 
the warranty period or are forever waived. 

3  

The foregoing warranty is exclusive of any other warranties, express, implied or statutory. 
In particular, this warranty shall not apply to failure arising from defect in design when the 
design has been completed in part by the Customer or a third party. Unless otherwise agreed, 
the warranty shall not apply to the compliance of Products to Customer’s needs. Should the 
Products warranty be breached, Customer’s exclusive remedy against Solar Stik, and Solar 
Stik’s sole obligation, shall be limited to, at Solar Stik’s option, repairing or replacing the 
defective Products. 

4  

The Product shall be considered defective if the failure may be duplicated by Solar Stik, it being 
understood nonconformity shall be determined by reference to the contractual specifications 
applicable to the allegedly defective Products.

Warranty and Returns

Summary of Contents for PDM 3000

Page 1: ...Solar Stik Inc OPERATOR AND MAINTENANCE MANUAL FOR THE POWER DISTRIBUTION MODULE PDM 3000 Updated 20200428 DISTRIBUTION STATEMENT A Approved for public release distribution is unlimited Revision A It...

Page 2: ...st Foreign Object Intrusion 8 Heat 8 Equipment Description The Inter Connect System 9 PDM 3000 Connections 11 Power Input 11 Power Output 11 Regulated Power Output 12 PDM 3000 Information Plate I Plat...

Page 3: ...ont 11 Figure 5 PDM 3000 left side 11 Figure 6 PDM 3000 right side 12 Figure 7 PDM 3000 bottom 12 Figure 8 PDM 3000 top Faceplate specs and cautions 13 Figure 9 PDM 3000 output breakers 14 Figure 10 C...

Page 4: ...used in concert with other Solar Stik components The modular design allows the operator to use it with other technologies capabilities that collectively meet the specific mission requirements for an...

Page 5: ...ing equipment Live power may be present Figure 2 PDM 3000 Safety Information Labels Your safety and the safety of others is very important Always read and obey all safety messages This is the safety a...

Page 6: ...nters labs and telecommunication rooms Using the Fire Extinguisher When using the extinguisher on a fire remember PASS Pull the pin Aim the nozzle or hose at the base of the fire from a safe distance...

Page 7: ...otect against electrocution Always Work with another person in case an emergency occurs Disconnect power before performing maintenance Wear safety glasses whenever working on any part of a System that...

Page 8: ...laced upright especially during inclement weather Impact Equipment should not be dropped onto hard surfaces at a height greater than one foot when transporting or during operation Dust Foreign Object...

Page 9: ...circuit It ensures the potential for a reverse polarity connection within the circuit is minimized If a problem occurs in a leg of the Inter Connect Circuit the affected leg will disconnect from the...

Page 10: ...020 Solar Stik Inc 10 Figure 3 Inter Connect plug The Inter Connect Plug Polarized 200 A maximum current 24 VDC connection only Mechanically locks into place Rotate knob clockwise to lock counterclock...

Page 11: ...input if required Figure 4 PDM 3000 front Figure 5 PDM 3000 left side The 24VDC Input Only Inter Connect port allows the PDM 3000 to use the Solar Stik HPS Inter Connect circuit as a power source PDM...

Page 12: ...regulated 28 0 VDC power to a load The 100 A breakers on the right side also serve as power switches for engaging and disengaging power circuits to the 24 VDC NATO and 28 0 VDC Amphenol ports Note Bot...

Page 13: ...13 April 2020 Solar Stik Inc Operator and Maintenance Manual for the PDM 3000 PDM 3000 Information Plate I Plate Figure 8 PDM 3000 top Faceplate specs and cautions...

Page 14: ...source e g Solar Stik HPS PRO Verter or Power Hub DC bus The choice of HPS Inter Connect port will depend on the HPS configuration Contact Solar Stik Technical Support 1 Turn off both breakers during...

Page 15: ...or cable options 4 Use a NATO slave cable to connect load to 24 NATO port to a load tower 28 0 VDC Load 24 0 VDC Load Figure 11 Connecting a voltage sensitive 28 0 VDC load to the PDM 3000 Figure 12 C...

Page 16: ...uch as possible Keep unused connector covers closed to prevent water dust intrusion Check the integrity of electrical connectors on a monthly basis Turn off loads when they are not in use This will sa...

Page 17: ...e the component in the most dry environment possible for a time long enough that any remaining moisture inside will dry When it is dry reintegrate the component to the System and test it to determine...

Page 18: ...missing items 2 Clean excessive dust or dirt accumulation from the exterior interior and connectors and from the cutouts on the bottom 3 Close all unused port covers If the case is broken or split or...

Page 19: ...Manual for the PDM 3000 Transporting Components The PDM 3000 carries like a briefcase using the case handles arrow There are no transport restrictions It is safe for all modes of transportation includ...

Page 20: ...fficiency 95 Safety Breaker s 1 100 A unregulated DC output breaker 1 100 A regulated DC output breaker Fuse s 1 200 A catastrophic fuse Reverse Polarity Polarized connectors Ground Fault Grounding lu...

Page 21: ...he Products shall be free from defects in materials and workmanship and shall conform to the contractual specifications or to specification sheet of the Product This warranty does not cover defects or...

Page 22: ...Operator and Maintenance Manual for the PDM 3000 April 2020 Solar Stik Inc 22...

Page 23: ...renewable energy power generation systems with detailed explanation of system components Advanced configuration options with hands on deployment of actual systems will enhance student understanding So...

Reviews: