fastening.  Fix  the  SmartBracket  with  the  set’s  assembling  units  only!  Other  fi  xing 
system use, for example, self-tapping screws of big diameter, can damage fastening 
clip. Together with self-tapping screws, there is a double stick tape in the set. It can be 
used for temporary sensor fi xing only. It is recommended not to use the tape for the 
permanent fi xing, as the tape is drying up over a time and the sensor may fall down 
which can interfere with its functions or even cause a breakdown.

 

Be  careful  while  SmartBracket  installing.  Overexertion  while  installing  can  cause 

deformation and, as a result, impossibility to install the sensor or to its unreliable fastening. 
Fix  the  SmartBracket  with  the  set’s  assembling  units  only!  Other  fi  xing  system  use,  for 
example,  self-tapping  screws  of  big  diameter,  can  damage  fastening  clip.  Together  with 
selftapping screws, there is a double stick tape in the set. It can be used for temporary sensor 
fi xing only. It is recommended not to use the tape for the permanent fi xing, as the tape is 
drying up over a time and the sensor may fall down which can interfere with its functions or 
even cause a breakdown. 

5.3 Install the fastening clip SmartBracket on the wall with a help of the expansion bolts and 

self-tapping screws included in the set (PICTURE 2). The sensor is not to be fastened directly 
to the glass! 

5.4 Put the sensor on the SmartBracket. Once the sensor is fi xed on the SmartBracket, its 

light must blink. It means that the tamper on the sensor is shut. In case the sensor does not 
blink, the tamper status must be checked at the receiver confi guration software!  

5.5 The sensor is installed!  
5.6  Make  sure  that  curtains,  house  plants,  furniture  and  other  objects  do  not  cover  the 

sensor’s microphone. Its small opening is on the front panel. In case there are curtains of 
dense  texture  on  windows,  the  sensor  is  to  be  installed  between  the  curtains  and  the 
window, for example on window jamb. Otherwise, the curtains might silence the sound of 
glass crash sound. 

5.7  With  a  help  of  receiver’s  confi  guration  software,  select  the  necessary  level  of  the 

sensor’s sensitivity. It is necessary that the sensor will not react to the background noise in 
the room. To perform a check, the device imitating the high-frequency glass breaking sound 
is  necessary.  In  case  there  is  no  such  device,  a  light  metal  object  can  be  used,  such  as  a 
spoon. With confi guration application, choose detection zone test to put the sensor to the 
detection  zone  test  mode  (the  receiver’s  manual  explains  how  to  accomplish  it).    In  the 
detection  zone  test  mode,  the  sensor’s  light  is  on  permanently,  switching  off  when  the 
alarming sound is registered – it is very easy to observe. In order to check the sensor, fi st a 
solid surface (preferably a glass one, without breaking it). The sensor must react to a low-
frequency  sound  by  switching  off  the  light  for  0.2  seconds.  When  it  happens,  during  1.5 
seconds throw a metal object (such as a spoon) to the solid surface or tap the glass with a 
spoon. The sensor will switch off the light for one second. It means that in security mode 
the sensor will react to the glass breaking. Reduce the sensor’s sensitivity and repeat the 
check  until  the  sensor  stops  reacting  to  alarming  sounds.  Then,  get  back  to  the  previous 
sensitivity level when the sensor was reacting normally. Thus, the sensor’s false triggering 
probability  is  reduced  and  the  reliable  protection  is  guaranteed.  For  the  maximum 
protection  from  the  false  triggering,  switch  on  all  devices  which  normally  function  in  the 
room – generator units, air-conditioning, etc. In a case, these devices’ turning on from time 
to time provokes the sensor’s triggering, the location for its installation should be chosen 
more carefully. 

5.8 In order to connect an additional wire opening sensor, plug in its wire to the socket “4” 

(PICTURE 3) and pass the wire through the opening of the main unit having broken out the 
cover 5 on the body frame (PICTURE 3). 

5.9 In “security” mode if the glassbreak is detected, the sensor sends the alarm signal not 

more frequently than once in 5 seconds switching on the light simultaneously. 