background image

15

INSTALLATION MANUAL

PV MODULES: P/M SERIES

ANNEX: MECHNICAL AND ELECTRICAL RATINGS

Standard Test Conditions are: irradiance of 1 kW/m

2

, AM 1.5 spectrum, and cell temperature 

of 25° C. Pmax of any individual module will be within 0 ~ + 3 % tolerance of these specified 

values. Specifications and electric characteristics in Tables 1/2 are subject to technical and 

product innovations. Information in this document is subject to change without notice.

Table 1: Specifications for P -series photovoltaic modules under STC

Type of cells

Type of 
Module

Maximum 

power

Pmax (W)

Operating 

Voltage

Vmp (V)

Operating 

Current

Imp (A)

Open Circuit 

Voltage

Voc (V)

Short Circuit 

Current

Isc (A)

Max. Series 

Fuse Rating 

(A)

Overall

Dimension

(mm)

Weight

(Kg)

60 poly-

crystalline 

cells

(156 x 156  mm)

P series

265 W

30.43

8.71

38.40

9.17

15

1650 × 990 × 35

18.6

270 W

30.62

8.82

38.49

9.25

15

275 W

30.83

8.92

38.80

9.33

15

280 W

31.08

9.01

39.01

9.43

15

285 W

31.25

9.12

39.21

9.51

15

Type of cells

Type of 
Module

Maximum 

power

Pmax (W)

Operating 

Voltage

Vmp (V)

Operating 

Current

Imp (A)

Open Circuit 

Voltage

Voc (V)

Short Circuit 

Current

Isc (A)

Max. Series 

Fuse Rating 

(A)

Overall

Dimension

(mm)

Weight

(Kg)

60 mono-

crystalline

cells

(156 x 156  mm)

M series

285 W

31.64

9.00

39.01

9.55

15

1650 × 990 × 35

18.6

290 W

31.77

9.13

39.24

9.66

15

295 W

32.00

9.22

39.43

9.75

15

300 W

32.23

9.31

39.65

9.84

15

305 W

32.42

9.41

39.86

9.93

15

Table 2: Specifications for M -series photovoltaic modules under STC

Type of cells

Type of 
Module

Maximum 

power

Pmax (W)

Operating 

Voltage

Vmp (V)

Operating 

Current

Imp (A)

Open Circuit 

Voltage

Voc (V)

Short Circuit 

Current

Isc (A)

Max. Series 

Fuse Rating 

(A)

Overall

Dimension

(mm)

Weight

(Kg)

72 poly-

crystalline

cells

(156 x 156  mm)

P series

335 W

37.82

8.86

46,95

9.32

15

1968 × 990 × 40

22.3

340 W

38.04

8,94

47.21

9.40

15

345 W

38.21

9.03

47.40

9.48

15

Table 3: Specifications for P -series 72 cell photovoltaic modules under STC

Summary of Contents for M Series

Page 1: ...tors and licensed electricians Please read this manual carefully before installing or using the modules Please be aware that there is a serious risk of various types of injury occurring during the installation including the risk of elec tric shock All P M series PV modules are equipped with a permanently attached junction ter minal box that will accept variety of wiring applications or with a spec...

Page 2: ...aged In case the glass surface of a PV modu le is broken wear goggles and tape the glass to keep the broken pieces in place ELECTRICAL SAFETY Contact with electrically active parts of a PV module such as terminals can result in burns sparks and lethal shock whether the PV modules is connected or not PV modules produce electricity when the sunlight or other sources illuminate the module surface Whe...

Page 3: ...e frame Do not repair glass back sheet or other broken part of the module Please install with dry tools in dry con dition Do not operate when the module is wet unless wear proper equipment against electrical shock Do not grab the PV module at only one side The frame may bend Grab the PV module at two sides facing each other Do not touch the PV module with bare hands The frame of PV module has shar...

Page 4: ...rom dropping out of the frame in case the glass is broken Cables shall be located so that they will not be exposed to direct sunlight after ins tallation to prevent degradation of cables When installing the module make sure that the terminal box is on the higher side of the module for better waterproof 4 COMPONENTS 5 SITE SELECTION AND WORK ENVIRONMENT In most applications the PV modules should be...

Page 5: ...PV modules where the salt water damage may be pos sible please consult with Solar Fabrik local agent first to determine an appropriate in stallation method or to determine whether the installation is possible P M series PV modules have also pas sed salt mist corrosion test according to IEC60701 But corrosion may occur in the module frame connecting to the bracket portion or the portion of ground c...

Page 6: ...re 3 PARALLEL for more current Please be careful in arranging the system ground so that the removal of one module from the circuit will not interrupt the groun ding of any other modules The modules should be grounded to the same electrical point Anexampleofacceptablegroundconnec tion using a screw nut hardware not provided and washer retaining a ground screw is shown in figure 4 The size of the gr...

Page 7: ...d Solar Fabrik does not specify or warrant frame clips The P M series modules warranty may be void if customer selected frame clips which are improper or inadequate with respect to the module properties inclu ding strength or material or installation Note that if metal clips are used there must be a path to ground from the clips for instance using star washers in the clip hardware set Please revie...

Page 8: ...the long edge of module 4 clips are usually adop tive If additional wind or snow loads are anticipated for this installation increase the number of clips to 6 or 8 as required System designer and installer are respon sible for load calculations and for proper design of support structure 12 MAINTENANCE The modules are designed for long life The regular inspection and maintenance of the module must ...

Page 9: ...cation C as shown in Figure 1 back view of the module Figure 2 mounting detail and Figure 3 parts detail The modules are fastened with four M6 bolts Mounting Using Clips on Long Edge of Module Long Edge Parallel to Array Rails The modules may be mounted using clips clamps designed for solar modu les as shown in Figures 4 and 5 Note that the clip positions are important the clip centerlines must be...

Page 10: ...he array rails are per pendicular to the long sides as shown in Figure 7 The clip centerlines must be between 300mm and 350mm from the ends of the module Note that the mounting clips should meet the mini mum dimensions catch width of 5mm and length of 30mm shown in Figure 4 The array rails must support the bottom of the modules and must be continuous pieces no breaks in the rail The maxi mum snow ...

Page 11: ...protection of module and cable from over current and or blocking diode for preventi on of unbalanced strings voltage to block the reverse current flow 3 WARNING Do not stand or step on the PV module Glass Frame Film and Terminal box Under normal conditions a photovoltaic module is likely to experience conditions that produce more current and or voltage than reported at Standard Test Condi tions Ac...

Page 12: ...ule Figure 2 moun ting detail and Figure 3 parts detail The modules are fastened with four M8 bolts Mounting Using Clips on Long Edge of Module Long Edge Parallel to Array Rails Figure 5 The modules may be mounted using clips clamps designed for solar modu les as shown in Figures 4 and 5 Note that the clip positions are important the clip centerlines must be between 240mm and 290mm from the end of...

Page 13: ...ule when the array rails are per pendicular to the long sides as shown in Figure 7 The clip centerlines must be between 240mm and 290mm from the ends of the module Note that the mounting clips should meet the mini mum dimensions catch width of 5mm and length of 30mm shown in Figure 4 The array rails must support the bottom of the modules and must be continuous pieces no breaks in the rail The maxi...

Page 14: ...e for protection of module and cable from over current and or blocking diode for preventi on of unbalanced strings voltage to block the reverse current flow 2 WARNING Do not stand or step on the PV module Glass Frame Film and Terminal box Under normal conditions a photovoltaic module is likely to experience conditions that produce more current and or voltage than reported at Standard Test Condi ti...

Page 15: ...49 9 25 15 275W 30 83 8 92 38 80 9 33 15 280W 31 08 9 01 39 01 9 43 15 285W 31 25 9 12 39 21 9 51 15 Type of cells Type of Module Maximum power Pmax W Operating Voltage Vmp V Operating Current Imp A Open Circuit Voltage Voc V Short Circuit Current Isc A Max Series Fuse Rating A Overall Dimension mm Weight Kg 60 mono crystalline cells 156x156 mm M series 285W 31 64 9 00 39 01 9 55 15 1650 990 35 18...