Solar Energy WWKS Installation And Operating Manual Download Page 3

  

3

Manual 

WWKS

A

Hot water

B

Heating inflow R1“

C

Circulation return line R¾“

D

Heating return line R1“

E

Cold water / draining R1“

F

Anode not insulated

G

Sensor heating zone

H

Plug G1 1/2“, insulation and cover

I

Blind flange with EPDM diaphragm gasket

J

Plug 1 1/4“

K

Solar return line G1“

L

Solar inflow G1“

M

Mounting solar expansion vessel

Sensor position:

1

Solar zone

A

F

I

L

1

J

C

K

E

Pic.: WWKS-1SST

G

M

L

1

K

I

L

1

K

M

I

Pic.: WWKS

F

G

L

1

I

J

E

K

D

C

B

A

Technical Data

WWKS tank with 2 registers

200

300

400

500

750*

1000*

Net volume [l]

184

295

380

470

750

995

Diameter [mm]

540

600

700

700

910

1010

Height [mm]

1473

1834

1591

1961

2000

2025

Tilted height [mm]

1514

1876

1712

2044

2072

2135

Weight [kg]

85

106

130

140

217

275

permissible operating temperature of service water [°C]

95

95

95

95

95

95

permissible operating pressure of service water [bar]

10

10

10

10

10

10

permissible operating temperature of solar circuit [°C]

110

110

110

110

110

110

Heating surface of solar panel [m

2

]

0,90

1,41

1,81

1,95

1,93

2,45

Volume of solar heat exchanger [l]

6,3

9,8

12,7

13,6

13,5

17,1

Heating surface of heating panel [m

2

]

0,7

0,8

1,0

1,28

1,17

1,12

Volume of heating panel [l]

4,9

5,7

7,0

8,9

8,2

7,9

Standby loss 24h [kWh]

2,3

2,6

2,9

3,2

3,7

4,8

Key performance indicator NL below 

4,2

7,5

15,2

19,1

21

26

Key performance indicator NL above 

1,1

2,2

3,4

5,9

6,2

7,1

WWKS-1SST tank 

with 1 re SST premounted

200

300

500

Weight [kg] (w/o SST)

59

83

-

114

-

-

Heating surface of solar panel [m

2

]

0,9

1,41

-

1,95

-

-

Volume of solar heat exchanger [l]

6,3

9,8

-

13,6

-

-

*SST25 - only wall mounting possible

Technical Data