14
EN
7. Operation
7.1 ATLAS GREEN
Switching the laser on / off
On:
Turn the on/off switch, transport lock to the right (ON position) and the pendulum unit will be released.
The device transmits the horizontal 360° line from the output aperture. To turn off the vertical 360° line,
press V on the keypad.
The instrument will level itself automatically within the specified inclination range
(see Chapter 3/Technical data).
Off:
Turn the on/off switch, transport lock to the left (OFF position) and the pendulum unit will be locked;
the laser lines will disappear.
NOTE
Magnets can affect the measurement instrument and lead to false results.
If the vertical laser line is not projected vertically to the wall or to the target surface, uneven surfaces can
lead to erroneous measurement results.
Make sure that the vertical laser line is projected vertically to the wall or to the target surface.
Severe temperature fluctuations can lead to erroneous measurement results.
Before start-up, allow the device to acclimatise to the environmental conditions.
The laser lines will flash every 30 seconds when the battery capacity falls below 10%.
Recharge the battery regularly or ensure additional batteries are available.
7.1.2 PULSE mode
The REC LRD0 receiver can be used to detect the laser lines at even greater distances or in unfavourable
environmental conditions. The pulse mode is active at all times for the ATLAS.