Generation 2 Fortress Battery-eVault18.5
Batt Capacity: 360Ah x #Parallel_Batteries
Max A Charge: 150A (100A for life) x #Parallel_Batteries
Max A Discharge: 160A x #Parallel_Batteries
Max A Grid Charge: 100A x #Parallel_Batteries
TEMPCO: 0mV/C/Cell
BMS Lithium Batt: 04
Float V: 54.2V
Absorption V: 54.4V
Equalization V: 55.5V
Equalization Days: 30
Equalization Duration: 1 Hours (tops off battery)
Recommended Shutdown V / Percentage: 51.3V & 20%
Recommended Low Batt V / Percentage: 51.7V & 30%
Recommended Restart V / Percentage: 51.9V & 40%
Battery Resistance: 5mOhms
Battery Charge Efficiency: 99%
Battery Empty Voltage: 46V
Simpliphi Power: PHI 3.8 Battery 48V
Batt Capacity: 75Ah x # Batt
Max A Charge: 37.5A x # Batt (20A for better lifespan)
Max A Discharge: 37.5A x # Batt (34A for better lifespan)
Max A Grid Charge: 20A x # Batt
TEMPCO: 0mV/C/Cell
BMS Lithium Batt: Not Selected
Float V: 55.6V
Absorption V: 56V
Equalization V: 56V
Equalization Days: 30
Equalization Duration: 2 Hours (tops off battery)
Recommended Shutdown V / Percentage: 50.2V & 20%
Recommended Low Batt V / Percentage: 50.6V & 30%
Recommended Restart V / Percentage: 51.0V & 40%
Battery Resistance: 24mOhms ÷ (battery Count)
Battery Charge Efficiency: 99%
Battery Empty Voltage: 46V
Blue Ion 2.0 Battery
Batt Capacity: 40Ah x #Parallel_Batteries
(4 Parallel = 160Ah, 6 = 240Ah, 8 = 320Ah)
Max A Charge: 160A w/ 4 Batteries, 185A w/ 6+
Max A Discharge: 160A w/ 4 Batteries, 185A w/ 6+
Max A Grid Charge: 160A w/ 4 Batteries, 185A w/ 6+
TEMPCO: 0mV/C/Cell
BMS Lithium Batt: 03 (eGauge) / 00 (Namaka Box)
Float V: 55.2V
Absorption V: 55.2V
Equalization V: 55.2V
Equalization Days: 30
Equalization Duration: 1 Hours (tops off battery)
Recommended Shutdown V / Percentage: 47.0V & 20%
Recommended Low Batt V / Percentage: 49.0V & 30%
Recommended Restart V / Percentage: 52.0V & 40%
Battery Resistance: 5mOhms
Battery Charge Efficiency: 99%
Time
Watts
SOC
GridCharge
1:00AM
6000*Par_Batts
40%
5:00AM
6000*Par_Batts
40%
9:00AM
6000*Par_Batts
40%
1:00PM
6000*Par_Batts
40%
5:00PM
6000*Par_Batts
40%
9:00PM
6000*Par_Batts
40%
Time
Watts
SOC
GridCharge
1:00AM
1000*Batts
40%
5:00AM
1000*Batts
40%
9:00AM
1000*Batts
40%
1:00PM
1000*Batts
40%
5:00PM
1000*Batts
40%
9:00PM
1000*Batts
40%
Time
Watts
SOC
GridCharge
1:00AM
8000*Par_Batts
40%
5:00AM
8000*Par_Batts
40%
9:00AM
8000*Par_Batts
40%
1:00PM
8000*Par_Batts
40%
4:00PM
8000*Par_Batts
40%
9:00PM
8000*Par_Batts
40%
These settings will charge the batteries off solar only.
Discharge the batteries down to a maximum of 40% full.
Limited To Home mode will not sell to the grid from the
batteries (only the home will use battery power). The
100% time slot is to ensure that the batteries are
properly cycled each day.
These settings will charge the batteries off solar only.
Discharge the batteries down to a maximum of 40% full.
Limited To Home mode will not sell to the grid from the
batteries (only the home will use battery power).
These settings will charge the batteries off solar only.
Discharge the batteries down to a maximum of 40% full.
Limited To Home mode will not sell to the grid from the
batteries (only the home will use battery power).
Summary of Contents for 8K-2P-N
Page 5: ...October 26th 2022 5 Spec Sheet ...
Page 9: ...October 26th 2022 9 Diagram 2 Diagram 3 ...
Page 10: ...October 26th 2022 10 Note PV fuses are only required for 2 strings per MPPT Diagram 4 ...
Page 12: ...October 26th 2022 12 GUI Screens Main Menus Basic Setup ...
Page 13: ...October 26th 2022 13 c Battery Setup Grid Setup ...