97
21. MISSING LINE MEASUREMENT
• When
[S/%]
is pressed, the distance between two points
(S) is displayed as the gradient between two points.
• Press
[MEAS]
to observe the starting position.
"PROCEDURE Measuring using observation"
• When
[MOVE]
is pressed, the last target measured
becomes the new starting position to perform missing line
measurement of the next target.
"21.2 Changing the Starting Point"
6. Press
{ESC}
to end missing line measurement
• Missing line measurement results cannot be recorded when point names for 1st and/or 2nd target are null.
Always input point names for both targets.
It is possible to change the last measured point to the next starting position.
PROCEDURE
1. Observe the starting position and target.
"21.1 Measuring the Distance between 2 or more
2. After measuring the targets, press
[MOVE]
.
Press
[YES]
.
• Press
[NO]
to cancel measurement.
21.2 Changing the Starting Point
MLM
SD
HD
VD
20.757m
27.345m
1.012m
REC
MOVE
MEAS
MLM
Move 1st meas ?
MLM
SD
ZA
HA-R
NO
YES