1. Collimate the first target "A".
2. Set the horizontal angle of target "A" to
0°00'00".
Press
[0 SET]
, and it flashes. Press
[0 SET]
again at
once, and the horizontal angle of target "A" is set to
0°.
3. Collimate the second target "B".
The horizontal angle and vertical angle of target "B",
which you want to know, are displayed.
1. Collimate the target center.
Make sure that setting is applicable to the measure-
ment conditions.
2. Press [MEAS].
Distance measurement starts.
• Press the trigger key when the iM is in the Obs
mode or when
[MEAS]
/
[STOP]
is indicated on the
display unit. You can start/stop measurement.
The results of the measurement are displayed.
Hereafter, the results are updated whenever mea-
surement is performed.
Press
[SHV]
, and the displayed contents are
changed.
[1] Slope distance/Vertical angle/Horizontal angle
[2] Slope distance/Horizontal distance/Height dif-
ference
Angular Measurement
0SET
P1
SHV
COORD
MEAS
Obs
PC
ppm
0
0
SD
ZA
HA-R
80° 30’ 15”
0° 00’ 00”
0SET
P1
SHV
COORD
MEAS
Obs
PC
ppm
0
0
SD
ZA
HA-R
80° 30’ 15”
120° 30’ 40”
0SET
P1
SHV
COORD
MEAS
Obs
PC
ppm
0
0
SD
ZA
HA-R
80° 30’ 15”
120° 30’ 40”
Target “A”
0°00'00"
Basic Key Operation
●
Power ON / OFF
●
Lighting up the reticle/keys
●
Switching target type
Target type can be switched only on the screen where the target symbol
(ex.
) is displayed.
●
Switching the Laser-pointer/Guide light ON/OFF
• After turning ON the laser-pointer/guide light, the laser beam is emitted
for 5 minutes, and then automatically switches OFF. But in the Status
screen and when target symbol (ex.
) is not displayed in the OBS
mode, the laser beam is not automatically turned off.
{ON}
(Press and hold:
About 1 second)
Power On
{ON}
(Press and hold:
About 1 second)
Power Off
[
]
Switches the reticle illumination and key light
On/Off
[SHIFT]
Switches between target types
Prism/Sheet/N-prism
(reflectorless)
[
]
(Press and hold
until a beep sounds)
Turns ON/OFF the laser-pointer/guide light
●
Softkey operation
Softkeys are displayed on the bottom line of the screen.
●
Inputting letters/figures
{F1}
to
{F4}
Select the function matching the softkeys
{FUNC}
Toggle between OBS mode screen pages (when
more than 4 softkeys are allocated)
{SHIFT}
Switch between numeric and alphabetic characters.
{0}
to
{9}
During numeric input, input number of the key.
During alphabetic input, input the characters
displayed above the key in the order they are listed.
{.}
/
{±}
Input a decimal point/plus or minus sign during
numeric input. During alphabetic input, input the
characters displayed above the key in the order they
are listed.
{
}
/
{
}
Move the cursor/selection item left/right or select
other option
{B.S.}
Delete a character on the left.
{ESC}
Cancel the input data.
{ENT}
Select/accept input word/value.
●
Selecting options
●
Switching modes
●
Others
{
}
/
{
}
Move the cursor up/down
{
}
/
{
}
Move the cursor/selection item left/right or
select other option
{ENT}
Accept
the
option
[ ]
From OBS mode (Observation Mode) to
Starkey Mode
[CNFG]
From Status mode to Config Mode
(Configuration Mode)
[OBS]
From Status mode to OBS Mode (Observation
Mode)
[USB]
From Status mode to USB mode
[DATA]
From Status mode to Data Mode
{ESC}
Return to the Status mode from each Mode
{ESC}
Return to the previous screen
Display Functions
0SET
P1
SHV
COORD
MEAS
Obs
PC
ppm
0
0
SD
ZA
HA-R
80° 30’ 15”
132° 40’ 20”
Target “A”
Target “B”
0°00'00"
132°40'20"
Horizontal angle
Distance Measurement
0SET
P1
SHV
COORD
MEAS
Obs
PC
ppm
0
0
SD
ZA
HA-R
80° 30’ 15”
120° 12’ 00”
Dist
Fine “ r ”
PC
ppm
0
0
STOP
STOP
P1
Obs
PC
ppm
0
0
SD
525.450m
ZA
HA-R
80° 30’ 10”
120° 10’ 00”
0SET
P1
SHV
COORD
MEAS
Obs
PC
ppm
0
0
SD
HD
VD
518.248m
525.450m
86.699m
Trigger key
Press the Starkey [ ], and the Starkey mode is accessed. In
the Starkey mode, it is possible to change the setting item
that is frequently used during measurement.
Prism constant value
Atmospheric correction factor
Remaining battery power
Tilt angle compensation
Page number
(Next page exists.)
Distance
Vertical angle
Horizontal angle
Softkey
Target
Prism
Reflective sheet
Reflectorless
Bluetooth
communication status
Level 3: Full power
Level 2: Plenty of power remains.
Level 1: Half or less power remains.
Level 0: Little power remains.
No power remains.
(flashing): Laser-pointer is
selected and ON.
(flashing): Guide light is selected
and ON.
: Connection established
(flashing)
(flashing)
: Waiting
(flashing) : Disconnecting
:
Bluetooth
device is OFF
: Connecting
Laser-pointer function/Guide light On
0SET
P1
SHV
COORD
MEAS
Obs
PC
ppm
0
0
SD
ZA
HA-R
OBS
DATA
USB
CNFG
Dist
Fine “ r ”
PC
ppm
0
0
STOP
$
T i l t c r n
:
Ye s ( H , V )
C o n t r a s t : 1 0
R e t i c l e l e v : 3
R e f l e c t o r : P r i s m
Ye s ( H , V )
Ye s ( V ) N o
Functions on
your instrument
Laser is emited
Input screen
Status screen
Measuring screen
Obs Mode screen
Next page exists.
Preceding page exists.
Input mode
A
A :Inputting capital letters and figures.
a
:Inputting small letters and figures.
No display: Inputting numerals.
Cd
: pole
Operator
Instrument name
JOB
Date
Time
iM-103
rec 49999
OBS
DATA
CNFG
USB
iM-103
S/N XX123456
Date Jan/01/2017
Time 09:39:12
rec 49999
S/N XX123456
Ver. X.XXXX_XX
X.XXX
Job. JOB1
Application
software
version
OBS
DATA
CNFG
USB
iM-103
S/N XX123456
I n t e r n a l P t . :50000
B l u e t o o t h
rec 49999
[SHIFT]
[SHIFT]
[B.S.]
[B.S.]
[ESC]
[ESC]
[FUNC]
[FUNC]
Enter key
[ENT]
[ENT]
[0]
[0] [ ]
[ ] [ ]
[ ]
[1]
[1] - [9]
[9]
Power key [ON]
[ON]
Starkey [ ]
Illumination key [ ]
[ ]
[ ]
[ ] [ ]
[ ] [ ]
[ ] [ ]
[ ]
Selector key for softkeys
Display unit
Nomenclature
2
1
6
4
3
5
7
8
9
11
10
12
13
14
15
2
16
19
17
18
21
20
22
24
23
25
26
27
1
Handle
2
Instrument height mark
3
Battery cover
4
Operation panel
5
Serial connector /
Combined communications
and power source connector
(Low Temperature Model)
6
Circular level
7
Circular level adjusting screws
8
Base plate
9
Levelling foot screw
10 Optical plummet focussing ring
11 Optical plummet eyepiece
(10,11: Not included on instruments
with laser plummet)
12 Display unit
13 Guide light
14 Objective lens (Includes Laser-
pointer function)
15 Handle locking screw
16 Tubular compass slot
17 Vertical clamp
18 Vertical fine motion screw
19 Trigger key
20 External interface hatch (USB port/
Reset button)
21 Horizontal fine motion screw
22 Horizontal clamp
23 Tribrach clamp
24 Telescope eyepiece screw
25 Telescope focussing ring
26 Sighting collimator
27 Instrument center mark
28 Plate level
29 Plate level adjusting screw
28
29
5
Low Temperature
Models only
iM-100_Quick_E.fm 2 ページ 2017年5月19日 金曜日 午後5時10分