the common can cause a ground loop, and your fixture may perform erratically. Test cables with
an ohm meter to verify correct polarity and to make sure the pins are not grounded or shorted
to the shield or each other.
4. Turn on the all units' power, the units begins reset, then the unit begins working. The slave
units will react the same as the master unit.
5. The units will react to the low frequencies of music via the internal microphone. Adjust the
audio sensitivity knob on the back of the master unit to make the unit more or less sensitive in
sound active. The panel has LED indicating for sound active.
Universal DMX Operation (DMX mode)
This mode allows you to use universal DMX-512 console to operate.
1. Install the units in a suitable position (laying or appending).
2. Use standard XLR microphone cable chain your units together via the XLR connector
on the rear of the units. For longer cable runs we suggest a terminator at the last fixture.
3. Assign a DMX address to each the unit using dipswitches, see the "DMX Address
Quick Reference Char".
4. Turn on the all units' power, the units begins reset, then the unit begins working.
5. Use DMX console to control your units.
Notes:
1. DMX console can not be used in Master-Slave operation (Sound Active or AUTO mode ).
2. There should be only one master unit in Master-Slave operation.
DMX Control
The system only accepts the DMX512 signal of international standard to control the
system mode, the light beam ON /OFF, running direction, running speed and twinkle
speed etc.
Page 2
Page 7
Don’t throw this product away just as general
trash, please dispose of this product following
the abandon electronic product regulation in your
country.
To protect the environment,
recycle packing material
wherever possible.
Do not remove or break the warranty label, otherwise it void the warranty.
Always replace with the exact same type fuse, replacement with anything
other than the specified fuse can cause fire or electric shock and damage your
unit, and will void your manufactures warranty.
There are no serviceable parts in the light. Please have all servicing and
adjustments made by a qualified service engineer.
When hanging this fixture, always secure it to a fastening device using a
safety cable (not provided).
Always make sure that you are connecting the light to the proper voltage, as per the
specifications in this manual or on the product's sticker. Never connect the light to a
dimmer pack. Make sure that the power cable is not cracked, crimped or damaged. Ne
The maximum ambient temperature (Ta) is 104 F (40 C). Do not operate the
fixture at a higher temperature. In case of a serious operating problem, stop
using this product immediately!
Use cleaning tissue to remove the dust absorbed on the external lenses
periodically to optimize light output.
Avoid direct eye exposure to the light source while the fixture is on. Always disconnect
the light from its power source before servicing. Always connect the light to a grounded
circuit to avoid the risk of electrocution.
This product is for indoor use only! Use only in dry locations. Keep this
device away from rain and moisture, excessive heat, humidity and dust. Do
not allow contact with water or any other fluids, or metallic objects.
Make sure there are no
flammable materials close to
the fixture(s) while operating.
Please prevent this light away
from electrical shock
Power
110V 240V
Ground
1
MASTER: SOUND/AUTO/DMX
2
SLAVE
DMX Signal
Light No 1
Light No 2
Light No 3
Light No ….
……...
2
SLAVE