8.2. Heater
Heating element (Resistance) is a component
which is desingned to regulate temperature of
water inside the drum. It has three connections:
Phase, notral and ground connections.
Resistance
Technical features
Heater type
Tubular heating element
with NTC – sensor
Nominal voltage
230 V
Nominal power
2000 W ±5%
Resistance
26.4 Ω ±5%
Termal fuse
2 sided
Testing component
Check the resistance value on the component with multimeter as shown below.
Resistance value should be between 26.4 Ω ±5%