In the non-editable fields
”Ext. humidity”
and
”Ext. temp.”
there are displayed current values of external
sensors. As this modification of the module is not equipped by external sensors, the values are always ”0”.
In the non-editable fields
”CPU Temp.”
and
”Batt. voltage”
there are displayed current values of processor
temperature and battery voltage of the module. These values are transmitted in each info-message (see description
of information message in section
”
Structure of WB169-SI2 module data message”).
The
”Send periode”
parameter is used for setting of broadcasting period of regular information messages. Value
of the period should be set in minutes; default setting is 60 minutes. For switching to external synchronization
mode, it is required to enter the number of synchronization port with ”-” (minus) sign. Broadcasting is disabled
by setting this parameter to zero value. More detailed description of this variable and possibilities of its setting are
explained in details in section
”
Commands for WMBUS messages settings”.
The
”Leak measure periode”
parameter is basic measuring interval of leak and burst functions. Its value is
factory set to 10 minutes and cannot be changed. Values of counters for
”
Leak” and
”
Burst” functions are checked
with this period.
Editable variables
”WMBUS Mode”
,
”WMBUS Channel”
and
”WMBUS Power”
are used for settings
of radio-frequency subsystem of the module. More detailed description of these variables and possibilities of their
setting are explained in details in section
”
Modem group commands”.
The
”WMBUS Mode”
parameter can be used for selection of the module’s WMBUS communication mode.
Factory setting is ”N1” mode, variable is entered by choosing from pre-set relevant options.
The
”WMBUS Channel”
parameter can be used for selection of the module’s frequency channel. Frequency
channels within particular frequency bands are defined by the M-Bus standard. Variable is entered by choosing
from pre-set relevant options (there are 7 options for WB169-SI2 module).
The
”WMBUS Power”
parameter can be used for selection of the module’s transmitting power. Factory setting
is 100 mW (moderate power), variable is entered by choosing from pre-set relevant options.
In the non-editable fields
”WMBUS recv. counter”
and
”WMBUS send counter”
there are displayed cur-
rent numbers of received and transmitted messages from the last reset of the module. These data can be used for
module’s diagnostics.
Some of the module parameters can be configured also by using of
”
BT-IRDA”
converter and
”
SOFTLINK
Configurator”
mobile application. Current version of the WB169-SI2 module supports configuring all parameters,
that are necessary for module installation on the site, as well as performing basic tests.
In the figure
there is an identification form of WB169-SI2 module (bordered by grey colour), form selection window
(bordered by yellow colour) and form for setting of
”
Leak” and
”
Burst” functions (bordered by blue colour).
Figure 10: Basic forms of WB169-SI2 module in
”
SOFTLINK Configurator” application
In the figure
there is a form for setting of inputs and outputs (bordered by violet colour) and encryption setting
form (bordered by green colour).
WB169-SI2
27