background image

Chapter 1 - Introduction

6

PBpro ETH - User Guide

1.3.3

Conventions used

The following conventions are used throughout Softing customer documentation:

Keys, buttons, menu items, commands and
other elements involving user interaction are
set in bold font and menu sequences are
separated by an arrow

Open 

Start

 

 

Control Panel

 

Programs

Buttons from the user interface are enclosed
in brackets and set to bold typeface

Press 

[Start]

 to start the application

Coding samples, file extracts and screen
output is set in Courier font type

MaxDlsapAddressSupported=23

Filenames and directories are written in italic

Device description files are located in 

C:

\StarterKit\delivery\software\Device
Description files

CAUTION

CAUTION indicates a potentially hazardous situation which, if not avoided,
may result in minor or moderate injury.

Note

This symbol is used to call attention to notable information that should be
followed during installation, use, or servicing of this device.

Hint

This symbol is used when providing you with helpful user hints.

1.3.4

Document history

Document
version

Release
date

Modifications compared to previous version

01

2014-04-30

Initial version

02

2014-07-10

Minor changes due to internal review:

Last chapter title "EC declaration by the
manufacturer" changed to "Declarations by the
manufacturer"

FCC statement added

ROHS compliance added

WEEE statement added

Summary of Contents for PBpro ETH

Page 1: ...Copyright 2014 Softing Industrial Automation GmbH Remote PROFIBUS Interface PBpro ETH User Guide Version MMA NN 012310 E 072014 02...

Page 2: ...r improvements to these instructions without prior notice The actual design of products may deviate from the information contained in the instructions if technical alterations and product improvements...

Page 3: ...ROFIBUS interfaces 10 2 5 Ethernet port 10 2 6 Light Emitting Diodes LED Chapter 3 12 PBpro ETH Administration 12 3 1 Built in web server 13 3 2 PBpro ETH information 13 System Status Information 3 2...

Page 4: ...te 3 3 4 4 26 Set password 3 3 4 5 26 Configuring access to PBpro ETH on a Windows PC 3 3 5 26 Install software 3 3 5 1 26 Configure driver 3 3 5 2 30 Reset to factory settings 3 3 6 Chapter 4 32 Tech...

Page 5: ...n the housing of the PBpro ETH It does not contain any parts that need to be maintained or repaired by the user In the event of a fault or defect return the unit to the vendor Opening the unit will vo...

Page 6: ...itten in italic Device description files are located in C StarterKit delivery software Device Description files CAUTION CAUTION indicates a potentially hazardous situation which if not avoided may res...

Page 7: ...s complete and free of defects In case of problems please contact your vendor 1 5 Intended Use The PBpro ETH has been designed for use in factory process and building control The unit must not be used...

Page 8: ...control cabinets The PBpro ETH is convection cooled It therefore needs to be installed in such a way that the ventilating ducts are at the top and bottom of the unit Ensure a ventilation space of at l...

Page 9: ...blows if an overvoltage of approx 30 V or higher occurs in the power supply or if a fault occurs in the device The safety fuse can only be replaced by the device manufacturer Important The starting c...

Page 10: ...es the power supply status This LED is on when the internal power supply is ensured If this LED is off the supply voltage 24 V is missing or the internal voltage generation is defective In the latter...

Page 11: ...e PB LED shows the bus activity of the corresponding interface Master The LED is on as soon as the master has received the token Slave The LED indicates the status data exchange Note The LED may also...

Page 12: ...ing the DHCP discover procedure The default hostname is composed of part number serialnumber e g http DEA NN 012314 133500005 Part number and serial number can be found on the type plate of the PBpro...

Page 13: ...ETH consisting of MAC Address fixed Ethernet MAC address IP Address IP address Subnet Mask IP subnet mask Broadcast Address IP broadcast address Default Gateway Address address of the IP gateway to ot...

Page 14: ...14 PBpro ETH User Guide 3 2 2 Hardware Diagnostics During start up of the device several hardware components of the system are tested The test result is shown in the following example Figure 3 Hardwar...

Page 15: ...l PROFIBUS interface for the first channel and up to three additional PROFIBUS modules for its multi channel veraiants All componentns as well as the entire device are identified by serial numbers and...

Page 16: ...mask and gateway IP address must be set accordingly This information is referred to as IP configuration The IP configuration can be changed via Ethernet by means of a Web Browser HTTP protocol or by t...

Page 17: ...he following IP ports Port 80 for HTTP PBpro ETH s web pages Port 2355 for discovery and configuration using the tool Search and Configure Port 2356 for controlling PBpro ETH using TCP IP sockets Port...

Page 18: ...18 PBpro ETH User Guide Figure 6 Search and Configure Devices By selecting the device and clicking Configure you can modify network parameters of the PBpro ETH without using its website Figure 7 Searc...

Page 19: ...overall network allowing data exchange between any two network stations in any two subnetworks The physical characteristics of the networks or of the transmission paths Ethernet Token Ring ISDN are of...

Page 20: ...notation the part of the subnet mask which corresponds to the net ID is filled with 1 digits the part corresponding to the host ID is filled with 0 digits Example of a subnet mask is 255 255 255 0 Wit...

Page 21: ...description below explains the establishment of a TCP IP connection to your PBpro ETH Such a connection makes it possible to change the preconfigured IP address of the PBpro ETH 1 Ask your network ad...

Page 22: ...address the subnet mask and the standard gateway address are shown To add a second IP address click the Advanced button f Click Advanced to add a second IP address Then click Add in the IP Addresses d...

Page 23: ...Configuration Device Configuration Firmware Update Set Password All configuration pages require a login name and a password to execute the functions The login name is config The password is config by...

Page 24: ...o ETH will be lost You have to use the new IP address to reestablish web access to the Pbpro ETH If an inconsistent network configuration is used it may be impossible to connect to the PBpro ETH again...

Page 25: ...the change process is indicated by the message Success in the browser window 3 3 4 4 Firmware update If a new version of the device s firmware becomes available it can be stored in the device using th...

Page 26: ...on a Windows PC 3 3 5 1 Install software The PBpro ETH software is part of the PBpro ETH Installation CD 1 Insert the CD into your CD drive 2 If Autorun is enabled on your system the startup page is...

Page 27: ...ministration PBpro ETH User Guide 27 2 Select PBproETH FG series and click Add Figure 10 Device Configuration 3 A dialog is opened allowing to enter modify symbolic naming of a PROFIBUS channel Figure...

Page 28: ...e default name Node n according to your needs 5 Click Next 6 In the next step you need to identify the the PBpro ETH either by its IP address or by its host name and select the assigned connection For...

Page 29: ...e control interval for monitoring the connection establishment to the PBpro ETH Max Idle Time Time control interval to monitor the connection DP Update Interval Update interval time for exchanging the...

Page 30: ...tion programs either via its symbolic name e g Node0 or via its unique interface number Examples for ready to use software are Softing s PROFIdtm free gateway DTM for FDT based parameterization and as...

Page 31: ...n also lead to permanent failure of the PBpro ETH Such damages are not covered by warranty To reset proceed as follows 1 Remove power from the PBpro ETH 2 Carefully insert the tip of a ball pen into t...

Page 32: ...tself DEA NN 012311 DEA NN 012312 DEA NN 012313 DEA NN 012314 Supply Voltage direct current 24V DC Supply Voltage Tolerance 20 incl ripple Typical Current Consum ption During Operation 0 2 A 0 3 A 0 4...

Page 33: ...nents of your installation DC adapter Industrial Ethernet devices etc also have to meet the EMC requirements A shielded cable must be used In addition the cable shield must be grounded properly CAUTIO...

Page 34: ...Chapter 5 Declarations by the manufacturer 34 PBpro ETH User Guide WEEE Electrical and electronic equipment must be disposed of separately from normal waste at the end of its operational lifetime...

Page 35: ...This page is intentionally left blank...

Page 36: ...r Allee 6 85540 Haar Germany Tel 49 89 4 56 56 0 Fax 49 89 4 56 56 488 Internet http industrial softing com Email info automation softing com Support support automation softing com Softing Industrial...

Reviews: