background image

Chapter 2 - Installation

FG-260 - Quick Startup Guide

11

2.1.2

Connection diagram

The following connection diagram gives an overview about the different plugs
and interfaces:

Summary of Contents for FG-260

Page 1: ...Copyright 2014 2015 Softing Industrial Automation GmbH Gateway between EtherNet IP and PROFINET with PROFINET Controller functionality FG 260 Quick Startup Guide Version MMA CA 010260 EN 072015 1 02...

Page 2: ...improvements to these instructions without prior notice The actual design of products may deviate from the information contained in the instructions if technical alterations and product improvements s...

Page 3: ...and dismounting 2 1 1 11 Connection diagram 2 1 2 12 Connecting the power supply 2 1 3 13 Connecting to network 2 1 4 15 Power up the device 2 1 5 16 2 2 Install software Chapter 3 17 Status indicator...

Page 4: ...FG 260 Quick Startup Guide 4 Table of Contents 28 5 2 Installation position and related ambient operating temperature TA Chapter 6 32 Declarations by the manufacturer...

Page 5: ...use in factory process and building control The unit must not be used in explosion hazard areas The permissible ambient conditions given in Chapter Technical Data must be complied with Note Faultless...

Page 6: ...kets and set to bold typeface Press Start to start the application Coding samples file extracts and screen output is set in Courier font type MaxDlsapAddressSupported 23 Filenames and directories are...

Page 7: ...device s surface will be heated up Avoid direct contact When servicing turn off the power supply and wait until surface has cooled down Note Do not open the housing of the FG 260 It does not contain...

Page 8: ...interrupt facility can always be reached easily Note Depending on the installation position the maximum ambient operating temperature may differ Refer to Technical Data for detailed information Insta...

Page 9: ...tartup Guide 9 Mounting 1 For mounting the FG 260 on a DIN rail 35 mm attach the two upper notches to the rail 2 Press the device down towards the rail until it locks into place Note Do not put stress...

Page 10: ...uick Startup Guide Dismounting To dismount the FG 260 from the DIN rail slide a screw driver horizontally underneath the housing into the locking bar slide the bar downwards without tilting the screw...

Page 11: ...Chapter 2 Installation FG 260 Quick Startup Guide 11 2 1 2 Connection diagram The following connection diagram gives an overview about the different plugs and interfaces...

Page 12: ...5 mm The ground connection wire must have a cross section of 1 5 mm Pin Signal Description 3 L Positive supply voltage 2 Functional Earth 1 GND Ground CAUTION The Functional Earth FE connection of the...

Page 13: ...cting to network The FG 260 provides the following network connections EtherNet IP and PROFINET Note We strongly recommend connecting the two Ethernet interfaces to different physical LAN networks Eth...

Page 14: ...rNet IP network The Ethernet interface labeled PROFINET is to be connected to a PROFINET network The Ethernet port corresponds to the IEEE 802 3 with the pin assignment shown below EtherNet IP Pin Sig...

Page 15: ...signal negative 3 RX Receive signal positive 4 Not used Drain wire 5 Not used Drain wire 6 RX Receive signal negative 7 Not used Drain wire 8 Not used Drain wire 2 1 5 Power up the device Turn on the...

Page 16: ...ch contains supplementary files such as this manual and the EDS file b Softing s Communication Configuration Tool ComConf and c the Search and Configure tool Search and Configure 4 Select the required...

Page 17: ...unning displays status on off ERR stands for error error information mapping application CFG stands for configuration displays configuration upload Net stands for Network displays EtherNet IP Network...

Page 18: ...The LEDs may be on permanently or flash in different colors and frequencies We use the following symbols Symbol Color Lighting none off red permanent green permanent red flashing 1 Hz green flashing...

Page 19: ...d alone mode LEDs Meaning PWR RUN green ERR CFG Start up phase approximate 20 seconds PWR RUN green green ERR CFG Device is running operational PWR RUN green green red ERR CFG Permanent hardware fault...

Page 20: ...green green red ERR CFG Primary device hardware failure A minor hardware failure has been detected during start up PWR RUN ERR CFG Primary Device failure A failure has been detected 3 2 PROFINET LED s...

Page 21: ...iguration failed PROFINET protocol has not been configured or Non volatile storage problem or Application watchdog is expired red red SF BF Address conflict detected The network communication may be d...

Page 22: ...ity EEPROM error red red SF BF Ethernet error Ethernet controller is not existing or not working properly red red SF BF General error 3 3 EtherNet IP LED statuses Net and Mod Network status Net LED Co...

Page 23: ...recoverable error Note An incorrect or inconsistent configuration is considered a minor fault steady red Major fault The device has detected a non recoverable error flashing green red Self test The d...

Page 24: ...device has not been configured flashing red Minor fault The device has detected a recoverable error Note An incorrect or inconsistent configuration is considered a minor fault steady red Major fault T...

Page 25: ...Startup Guide 25 4 Login to web server IP address information The default IP address for the Ethernet interface in the PROFINET LAN is 192 168 200 200 The IP address of the web server in the EtherNet...

Page 26: ...h And Configuration Tool in order to retrieve the current IP of the FG 260 2 Set the laptop IP address to 192 168 200 1 24 3 Open your browser and enter the the address http IP address of the FG 260 d...

Page 27: ...ambient operating temperature 40 C Storage temperature 40 C 85 C Altitude Must not exceed 2 000 m Location Indoor use only no direct sunlight Safety standard IEC EN UL 61010 1 Safety requirements for...

Page 28: ...28 FG 260 Quick Startup Guide 5 2 Installation position and related ambient operating temperature TA Depending on the installation position different ambient operating temperatures are allowed Horizon...

Page 29: ...0 mm 55 C 17 5 mm 65 C 50 mm minimum distance to the air inlet and air outlet Provide a minimum space of 50 mm to the air inlet and air outlet Thus you ensure a natural convection Rotated installation...

Page 30: ...Chapter 5 Technical Data 30 FG 260 Quick Startup Guide Vertical installation position...

Page 31: ...0 mm 40 C 17 5 mm 50 C 50 mm minimum distance to the air inlet and air outlet Provide a minimum space of 50 mm to the air inlet and air outlet Thus you ensure a natural convection Rotated installation...

Page 32: ...c and medical ISM radio frequency equipment group 1 class A EN 55022 Information technology equipment Radio disturbance characteristics Limits and methods of measurement class A EN 61000 6 4 Electroma...

Page 33: ...quate measures FCC This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable...

Page 34: ...Guide WEEE Electrical and electronic equipment must be disposed of separately from normal waste at the end of its operational lifetime Packaging material and worn components shall be disposed of acco...

Page 35: ...This page is intentionally left blank 35 FG 260 Quick Startup Guide...

Page 36: ...r Allee 6 85540 Haar Germany Tel 49 89 4 56 56 0 Fax 49 89 4 56 56 488 Internet http industrial softing com Email info automation softing com Support support automation softing com Softing Industrial...

Reviews: