Page 1: ...right 2014 Softing Industrial Automation GmbH Configuring a Softing echocollect to establish data exchange between a Siemens S7 300 and an Allen Bradley ControlLogix echocollect How to Version E 03201...

Page 2: ...r improvements to these instructions without prior notice The actual design of products may deviate from the information contained in the instructions if technical alterations and product improvements...

Page 3: ...ttings Chapter 3 7 Create a connection to the S7 300 PLC Chapter 4 9 Create a connection to the ControlLogix PLC Chapter 5 12 Create the table to establish data transfer from Data_to_S7 CLX to DB1 S7...

Page 4: ...This page is intentionally left blank...

Page 5: ...he source data block on the S7 300 is DB2 defined as one byte Software used Softing NetCon echo V4 33 Conventions The following conventions are used throughout Softing customer documentation Keys butt...

Page 6: ...ocollect port network settings 1 Start NetCon echo and configure the network settings of the echocollect port to be used We will use port 1 Eth 1 a Click on Station Own Station 1 b As a minimum the IP...

Page 7: ...tion to the S7 300 PLC echocollect How to 7 3 Create a connection to the S7 300 PLC 1 Click on Connection New Connection 2 Enter a connection name 3 Click on Logic Table Connection and select the PLC...

Page 8: ...Chapter 3 Create a connection to the S7 300 PLC 8 echocollect How to 4 After clicking OK select the TCP IP and Siemens S7 options 5 Enter the IP address of the S7 300 and click OK 6 Click OK again...

Page 9: ...o the ControlLogix PLC echocollect How to 9 4 Create a connection to the ControlLogix PLC 1 Click on Connection New Connection 2 Enter a connection name 3 Click on Logic Table Connection and select th...

Page 10: ...LC 10 echocollect How to 4 After clicking OK select the TCP IP and Rockwell CompactLogix ControlLogix options 5 Enter the IP address of the ControlLogix PLC and then click on Protocol Settings 6 Enter...

Page 11: ...Chapter 4 Create a connection to the ControlLogix PLC echocollect How to 11 7 Click OK 8 Click OK once again...

Page 12: ...5 Create the table to establish data transfer from Data_to_S7 CLX to DB1 S7 300 1 Click on Collect Collect Frame Table 2 Click on Graphic Display 3 Click on Table Add Table 4 Enter a name for the map...

Page 13: ...transfer from Data_to_S7 CLX to DB1 S7 300 echocollect How to 13 6 Click on the button next to Topic to select the data source connection CLX and click OK 7 Click on the button next to Item to select...

Page 14: ...to establish data transfer from Data_to_S7 CLX to DB1 S7 300 14 echocollect How to 8 Click OK 9 So far your table should look similar to this 10 To select the target data block on the S7 300 click on...

Page 15: ...Then check Use PLC Target and enter the address of the S7 300 target data block 12 To enable the data exchange create a timed trigger in the echocollect Click on Special Settings Trigger Settings 13 T...

Page 16: ..._from_S7 CLX 16 echocollect How to 6 Create the table to establish data transfer from DB2 S7 300 to Data_from_S7 CLX 1 Click on Table Add Table 2 Enter a name for the mapping table select the target P...

Page 17: ...Data_from_S7 CLX echocollect How to 17 4 Click on the button next to Topic to select the data source connection S7_300 and click OK 5 Type in the address of the source data block DB2 byte 0 in the It...

Page 18: ...transfer from DB2 S7 300 to Data_from_S7 CLX 18 echocollect How to 7 To select the target tag on the ControlLogix click on Special Settings PLC Target 8 Then check Use PLC Target and click on the butt...

Page 19: ...S7 CLX echocollect How to 19 10 To enable the data exchange create a timed trigger in the echocollect Click on Special Settings Trigger Settings 11 Then check Use Timeout and enter the trigger frequen...

Page 20: ...Chapter 7 Finished table mapping 20 echocollect How to 7 Finished table mapping CLX_to_S7 S7_to_CLX...