CAN Status LED 

Status 

off 

no power or in reset state 

flashing green 

in initialization state 

solid green 

CAN started 

flashing red 

CAN error passive 

solid red 

CAN bus off 

 

USB Status LED 

Status 

off 

no power or not recognized 

solid green 

connected and recognized 

solid red 

not (yet) recognized or 

error 

 

   

2  CAN Connector Pin Assignment 

Connector pinning complies to CiA standard DS 102.  

 

 
 
 
 
 
 
Pinning of the 9 pin

 D-Sub 

connector 

 

3 Status 

LEDs 

There are status LEDs for CAN and USB that show the current status. 
 
 
 
 
 
 
 
 
 

4 CE 

Information 

This device complies with the requirements of the EC directive 2004/108/EC  
"Electromagnetic Compatibility" (EMC directive). 

The product meets the following requirements: 

 

Emission:  EN61000-6-4 Generic emission Standard (industrial environments) 

EN55022 Class A (ITE Product Standard) 
EN55011 Group1 Class A (ISM Product Standard)  

 

Immunity:  EN61000-6-2 Generic Immunity Standard (industrial environments) 

A "Declaration of Conformity" in accordance with the above standards has been made and is 
filed at Softing Industrial Automation GmbH, Germany. 

NOTE:  

  To satisfy the EMC requirements, the equipment used (PC, monitor, CAN stations, etc.) 

also has to meet the EMC requirements. A shielded cable must be used. In addition, the 
cable shield must be grounded properly. 

 

Warning!

: This is a Class A product. In a domestic environment this product may cause radio 

interference in which case the user may be required to take adequate measures. 

 

5 RoHS 

Information 

CANpro USB is RoHS compliant. 

Pin Signal 

1 N.C. 

2 CAN_L 

Isolated GND  

4 N.C. 

Drain connected to connector 
shield (1M/2.2n to isolated GND) 

6 Isolated 

GND 

7 CAN_H 

8 N.C. 

9 N.C. 