background image

eazense 

POWERED BY SOFIHUB 

 |  SETUP AND INSTALLATION GUIDE

Dimensions:

Weight:

  

250 g

Included accessories: 

Installation guide
Drill hole template
3-year warranty

93mm

140mm

140mm

124mm

Summary of Contents for eazense

Page 1: ...SETUP AND INSTALLATION GUIDE ...

Page 2: ...the SOFIHUB website www sofihub com and select Portal This will be found at the top right of the home page and create your account Please select your location Australia New Zealand OR United States Canada Click Create Account and follow the prompts to claim your device ...

Page 3: ...RED BY SOFIHUB SETUP AND INSTALLATION GUIDE Next enter the MAC address of the radar found on the rear of the device and name the radar Your next step will be to subscribe to the monthly monitoring fee if applicable ...

Page 4: ...x and X Min are smaller than the actual size of the room then people outside this boundary may not be seen by the radar Values cannot exceed Y Max 6m X Min 3m X Max 3m The room height value must be greater than the radar height Once a fall is detected and the alarm is resolved it will take approximately 30 seconds for the radar to reset When any changes on X Y or radar height are made the unit wil...

Page 5: ...o mount the eazense radar choose a corner of the room which ensures the best coverage Take the guide template from the box and place it 2 2m from the floor Use the circles on the template as an indication where to place the screws Place the screws so they protrude approximately 10mm out ...

Page 6: ...from the radar sensor eazense to the PoE power injector or PoE router switch 2 Then connect the PoE power injector or PoE router switch to its power source 3 Connect a second ethernet cable to the LAN connection from the PoE injector or PoE router Once connected to a power source the eazense radar will be online and ready to be configured ...

Page 7: ... opposite corner of the room is which is represented by Y as well as the remaining corners of the room defined by X Max and X Min 1 Measure the Y axis then stand in the middle between X Max and Y Min 2 Measure distance to both 3 Values cannot exceed Y Max 6m X Min 3m X Max 3m Please define Y X Max and X Min as these values are required for the radar to work correctly Radar sensor Field of view Roo...

Page 8: ...en no falls are detected When a fall is detected the colour will change to RED This will also show on the main dashboard page PORTAL When a fall is detected an SMS with an alert will be sent to the nominated carer for action To reset the anomaly log in to the SOFIHUB portal dashboard and follow the steps ...

Page 9: ... TCP IP Encryption of data Centralised certificate management signed firmware Automatic OTA firmware update Notification SMS General Casing material ISOPAK 540 Colour White Power over Ethernet IEEE 802 3at type 1 PD Typical 3 9 W max 12 95 W Connectors Shielded RJ45 10BASE T 100BASE TX PoE Operating conditions room temperature Storage conditions room temperature Approvals EMC EN55032 class B CE MD...

Page 10: ...eazense POWERED BY SOFIHUB SETUP AND INSTALLATION GUIDE Dimensions Weight 250 g Included accessories Installation guide Drill hole template 3 year warranty 93mm 140mm 140mm 124mm ...

Page 11: ...Phone 1300 110 366 Email info sofihub com SOFIHUB COM ...