Operation Guide
Polar indication: automatically indicate,‘-’ means negative
polarity.
Over range Indication: ‘0L’ or ‘-0L’.
Sampling time: about 3 times/s
Unit display: with function and quantity of electricity unit
display
Automatic Power off time: 10 minutes
Power supply: 1.5V AAA battery ×2
Battery low voltage indication: LCD display symbol.
Temperature coefficient: < 0.1×accuracy degree/℃
Working temperature: 18℃
〜
28℃
Storage temperature: -10℃
〜
50℃
3.2. Technical Index
3.2.1. AC Current
Measurement
Distinguis
Accuracy degree
range
hability
60A 0.01A
400A 0.1A
400A
〜
600A 0.1A
Minimum input current:
0.2A AC current
Maximum input current:
600A AC current
Frequency range:
45
〜
65Hz
3.2.7. Line on-off test
Measurement Distinguis
Functions
range hability
Overload protection:
600V DC or AC (effective value)
4. Operation Guide
4.1. Readings Hold
During the measuring process, if the readings are required to
hold, slightly touch key, the display value will be locked,
slight press key again to cancel readings hold.
4.2. BackLight
1
)
In the process of measurement, if the ambient light is too
dim, causing reading difficulties, press key for more
than 2s, open BackLight and it will automatically off after
about 1 minute.
2
)
During the process if press key for more than 2s,
then the BackLight will be turned off.
4.3. Auto Power Off
1
)
If after 10 minutes when the meter is on without any
operation, it will go into hibernation and automatically shut
down to save power. Before the meter off, there will be one
sound of the buzzer to remind every 1 minute.
3.2.2. DC Current
Measurement
Distinguis Accuracy degree
range
hability
60A
0.01A
600A
0.1A
Minimum input current:
0.3A DC current
3.2.3. DC Voltage
Measurement
Distinguis Accuracy degree
range
hability
6V 0.001V
60V
0.01V
600V
0.1V
Minimum input voltage:
0.5V DC
Maximum input voltage:
600V DC
3.2.4. AC Voltage
Measurement
Distinguis Accuracy degree
range
hability
6V 0.001V
60V
0.01V
600V
0.1V
Minimum input voltage:
1.0V AC
Maximum input voltage:
600V AC (effective value)
Frequency range:
45 ~ 65Hz
3. Specifications
The meter should specify one year as a cycle to re-calibrate in the
conditions of 18℃
〜
28℃ and relative humidity less than 75.
3.1. Overview
Automatically select measurement function and range.
Overload protection for the whole measurement range.
Maximum allowable voltage between the measuring terminal
and the Earth: 600V DC or 600V AC
Work height: maximum 2000m
Display: LCD
Maximum display value: 6000 digits.
3.2.5. Frequency
3.2.5.1. Clamp head frequency measurement
(Pass A position):
Measurement
Distinguis Accuracy degree
range
hability
60.0Hz
0.1Hz
1000Hz
1Hz
Measurement range:
40Hz ~ 1000Hz
Input signal range:
≥2A AC current (effective value)
3.2.5.2. Pass V position:
Measurement
Distinguis Accuracy degree
range
hability
60.0Hz
0.1Hz
1000Hz
1Hz
Measurement range:
40Hz ~ 1000Hz
Input signal range:
≥0.8V AC voltage (effective value)
3.2.6. Resistance
Measurement
Distinguis Accuracy degree
range
hability
6kΩ
0.001kΩ
60kΩ
0.01kΩ
600kΩ
0.1kΩ
6MΩ
0.001MΩ
10MΩ
0.01MΩ
Overload protection:
600V DC or AC (effective value)
1Ω
If the resistance of circuit being
measured is less than 50Ω, then
the beeper in the meter may sound.
2
)
Press any key after auto power off to wake the meter into
working status.
3
)
When turn the meter on, hold the "NCV" key at the same
time, then the auto power off function is canceled.
4.4. Measurement Preparations
1
)
Turn the transfer switch, turn on the power. If the battery
voltage is low (of about ≤2.4V), the LCD will show “ ”
symbol, then the battery shall be replaced.
2
)
When the meter has not entered into measurement, it will
automatically enter into the status of automatic scan, the
meter displays as the following diagram shows.
4.5. Non-contact Voltage Detection (NCV)
1) Press NCV key for 2s, enable NCV function, the meter
displays.