11. Service and Support 

Monday through Friday from 8:30 a.m. to noon

Germany  

Ph.:  08 00 - 5 34 34 34

International 

Ph.: +49 - 26 04 - 97 70 

If you‘d like to contact us in writing, please use the contact form at the SOEHNLE homepage www.soehnle.com.

For contact information of SOEHNLE representative in your country, visit www.soehnle.com.

12. Guarantee  

SOEHNLE guarantees a rectification of faults based on material or production errors free of charge, either by 

repair or replacement, for 3 years as of the date of purchase. Please retain the receipt of purchase. In case of a 

guarantee claim, please return the scale with filled-in guarantee slip and receipt of purchase to your seller.  

Name

Address

Purchase date

Seller

Description of fault

Summary of Contents for WEB CONNECT

Page 1: ...WEB CONNECT Manual BMI ...

Page 2: ...ivate connection between web box and scale 8 2 6 Messages 8 2 7 Configure IP setting manually 9 2 8 Setting up the user account 10 2 9 Entering personal data I Unit of measurement kg lb st I Target weight 11 3 Weighing 12 4 The personal account 13 4 1 The main menu 13 4 2 Diagram display 13 4 3 Tabular display 14 5 Feedback 14 6 Deleting Account 14 7 Messages 15 8 Technical specifications 16 9 Dec...

Page 3: ...ot designed for medical and commercial use Please thoroughly read these instructions particularly the safety information and follow the instructions for care Please store these instructions for future use Further information can be found at our website at www soehnle com 1 2 Safety information Danger Improper use may result in hazards that may lead to death or severe injury Warning Improper use ma...

Page 4: ...dified Batteries contain chemicals A leakage of these chemicals could result in damages to objects or bodily injuries If battery acid comes into contact with the eye immediately rinse the eye with plenty of water and contact a physician Remove the batteries from the device if it is not used for a long time Notes The result may be falsified in the vicinity of cellular phones in the vicinity of heat...

Page 5: ...rweight 30 0 Adiposity 30 0 34 9 Adiposity level I 35 0 39 9 Adiposity level II 40 0 Adiposity level III 1 4 Rules for weighing The weight of an adult can change by approx 2 3 kg during one day For a reliable weight control it is therefore important to maintain constant weighing conditions That s why it s best to weigh oneself sober always at the same time the time between 6 p m and 8 p m is best ...

Page 6: ...ry compartment 6 Weighing cell 7 Measured value 8 Weak battery 9 Internet connection disrupted 10 Determine data for transmission 11 Data transmission 12 Body fat measurement not applicable with this device 13 Measurement unit 14 Power supply socket 15 Reset key 16 Broadband interface 17 Internet connection indicator 18 Network connection indicator 19 Power supply unit 20 Internet cable ...

Page 7: ...blished when both LEDs light up Troubleshooting should be performed according to the display if one or both LEDs flash WAN check internet connection LAN check router or connection to the router 2 4 Insert or replace batteries Open battery compartment of weighing platform Insert batteries Observe correct polarity Attention When replacing used batteries only use fresh batteries of the same type Neve...

Page 8: ...unicate with the router 1 Check the router power supply connection 2 Check the connection between web box and router LAN LED lights up WAN LED flashes Network is okay but the web box does not communicate with the network 1 If the DHCP function was activated on the router push reset key on web box to reset to factory settings 2 If the DHCP function was not activated on the router follow chapter 2 L...

Page 9: ...onnections 5 Click on LAN connection for WIN95 use right mouse button and select settings 6 Next to internet protocol mark TCP IP and select settings 7 You now have the choice to obtain the IP address automatically or to configure it manually Select Use following IP address and enter the following IP address 192 168 1 5 Subnet mask 255 255 255 0 and confirm 8 Now enter the following information in...

Page 10: ...ect Start and enter your user name and password Continue with Login 7 Enter the ID number of the web box bridge and the scale You will find these on the bottom of the respective product Note Please note that for synchronization scale and web box must be ready for operation and an internet connection must be established WAN and LAN LED light up Start synchronization 8 Step onto the scale within the...

Page 11: ...ould like to be addressed 4 Set up birthdate 5 Enter body height 6 Select activity level 7 Select desired unit of measurement for display kg lb st 8 Enter target weight 9 The user name can be changed here 10 If the password is to be changed this can be entered here 11 Email address can be changed here 12 Confirm entries with Save Note Personal data can be changed anytime It is also possibly to com...

Page 12: ...ot be saved 1 Step onto platform 2 The weight will be displayed Stand still during transmission and while data is being transmitted The data will be automatically allocated to your personal account Note In rare cases an automatic allocation to one account is not possible The user must then be allocated manually The user will receive a note in its personal account that data cannot be allocated to a...

Page 13: ...ere determined last and the difference to your desired weight will be displayed Links to the other information pages are available here Diagram display Table display My profile see chapter 2 7 1 4 2 Diagram display Select the period for review and the parameter to be displayed Use Filter data to individually adjust the period for review and the parameters to be displayed ...

Page 14: ... value you can edit this data or add a comment Use Add data manually to add weight values and comments without using the scale 5 Feedback Use My profile feedback to send us remarks regarding this program or the product 6 Deleting Account Use My profile delete account to delete your personal account All data will be irretrievably deleted after a security query and the corresponding confirmation ...

Page 15: ... Display while the product is being used Broadband error WAN LED flashes Check the internet connection Weak batteries Replace batteries 1 The connection between scale and web box has been interrupted 2 The scale is outside of the radio range Bring the scale back to the radio range of the web box Interrupt the power supply of the web box for 30 seconds Your measurement results cannot be transmitted...

Page 16: ... 100 g max 330 lb 0 2 lb 8 memory slots for individual persons Measurement current 0 1 mA RMS 50 5 kHz Radio frequency 434 MHz Batteries 4 x 1 5 V AAA batteries included in the scope of delivery As an alternative to regular alkaline batteries NiMh accumulator batteries with a low self discharge rate are also recommended Important Accumulator batteries must be recharged outside of the device ...

Page 17: ...noring this regulation may result in the user s permission to operate the appliance being withdrawn Electromagnetic influences Under extreme electromagnetic influences e g operating a radio controlled appliance in the immediate proximity of the appliance this may cause a detrimental effect to the display value When the cause of the disturbance ceases the appliance can be used again as intended or ...

Page 18: ... of SOEHNLE representative in your country visit www soehnle com 12 Guarantee SOEHNLE guarantees a rectification of faults based on material or production errors free of charge either by repair or replacement for 3 years as of the date of purchase Please retain the receipt of purchase In case of a guarantee claim please return the scale with filled in guarantee slip and receipt of purchase to your...

Page 19: ...007606 A 05 2013 EN JFS Quality Design by Leifheit AG Leifheitstraße 1 56377 Nassau Germany Telefon 49 2604 977 0 Fax 49 2604 977 300 www soehnle com ...