NB: All the dimensions are given in millimeters.
PENETRATION OF THE POST IN THE SOCKET: 350 mm
400
500
500
500
350
Dedicated to single use court or multi
-
sports
IMPLANTATION & SEALING :
COURT FOR DOUBLE GAME (DOUBLE
ALLEY
Court axle
Location of the sockets
-
Dig the holes for the sealing according to the
written dimensions.
-
Make the sealings with PJ 45 concrete dosed
by 350kg. Then putt he sockets in position,
using the dimensions given in the drawing
above. Be sure that the top of the sockets are
at the same level than the surface.
-
Let the concrete dry at least 72 hours.