background image

ASYS

16 A Transfer System

ENGLISH

IOMASY160810-GB_00

  

1

T

AblE

 

Of

 

CONTENTS

1.  C

ERTIfICATE

 

AND

 

CONDITIONS

 

Of

 

WARRANTy

 

2

2.  S

AfETy

 

3

2. 1.  I

mpORTANT

 

3

2. 2.  E

mERGENCy

 

3

2. 3.  p

ACkAGING

 

4

2. 4.  W

ARNING

 

4

3.  O

VERVIEW

 

5

3. 1.  p

URpOSE

 

Of

 ASyS TRANSfER SWITCH 

5

4.  U

NpACkING

 

AND

 

INSTAllATION

 

5

4. 1.  D

ElIVERy

 

AND

 S

TORAGE

 

5

4. 2.  I

NVENTORy

 l

IST

 

5

4. 3.  S

TORAGE

 

6

4. 4.  H

ANDlING

 

6

4. 5.  E

NVIRONmENTAl

 C

ONDITIONS

 

6

4. 6.  R

ACk

 m

OUNTING

 

6

4. 7.  E

NVIRONmENTAl

 

REqUISITES

 

7

5.  p

RESENTATION

 

7

5. 1.  f

RONT

 p

ANEl

 

7

5. 2.  R

EAR

 p

ANEl

 

7

5. 3.  O

pERATING

 p

ANEl

 

8

5. 4.  f

EATURES

 

8

6.  O

pERATING

 

pROCEDURES

 

9

6. 1.  m

ANUAl

 S

WITCH

 ON p

ROCEDURES

 

10

7.  T

ECHNICAl

 D

ATA

 

11

7. 1.  I

NpUT

/ O

UTpUT

 

fEATURES

 

11

7. 2.  C

ONNECTION

 

11

7. 3.  C

OmmUNICATIONS

 

12

7. 4.  m

ECHANICAl

 f

EATURES

 

12

7. 5.  E

NVIRONmENT

 

12

7. 6.  S

AfETy

 S

TANDARDS

 

13

7. 7.  EmC S

TANDARD

 

13

7. 8.  O

VERCURRENT

 

13

7. 9.  E

xTERNAl

 p

ROTECTION

 

AND

 I

SOlATION

 D

EVICES

 

14

8.  T

ROUblESHOOTING

 

15

Summary of Contents for Asys 16 A Transfer System

Page 1: ...INSTALLATION AND OPERATING MANUAL ASYS 16 A Transfer System IOMASY160810 GB_00...

Page 2: ......

Page 3: ...for a safe installation operation and use of the ASYS It is advised that this User Manual be consulted before installation of the equipment which operation should only be performed by skilled personne...

Page 4: ......

Page 5: ...Storage 6 4 4 Handling 6 4 5 Environmental Conditions 6 4 6 Rack Mounting 6 4 7 Environmental requisites 7 5 Presentation 7 5 1 Front Panel 7 5 2 Rear Panel 7 5 3 Operating Panel 8 5 4 Features 8 6 Op...

Page 6: ...d without SOCOMEC s written consent The period of validity of the warranty may never exceed 12 months after delivery Replacements repairs or modifications of parts during the warranty period cannot ex...

Page 7: ...humidity 20 to 85 no condensing Lay all cables so that nobody can stand on them or trip over them For pluggable equipment the socket outlet shall be installed near the equipment and shall be easily ac...

Page 8: ...by qualified technical person nel Even if the ASYS output has been switched off hazardous voltages are present within the ASYS any operation that requires the unit to be opened and or re moved may be...

Page 9: ...m with LED indicators capable of providing all information concerning equipment operation status together with the power source priority selection which enables trained operators to make full use of t...

Page 10: ...nd in an area protected from temperature extremes water and humidity and the presence of conductive powder or dust DO NOT stack units and do not place any objects on top of a unit Rack Mounting 4 6 Ta...

Page 11: ...Presentation 5 Front Panel 5 1 The front of the ASYS TRANSFER SWITCH with its LED display and interfaces Rear Panel 5 2 The back of the ASYS with its connectors terminals and interfaces 1 Output IEC3...

Page 12: ...source to auxiliary source ASYS is compatible with UPS providing sinusoidal output as well as direct main gen erating set and all sinusoidal source Break Before Make open transition transfer mode Bac...

Page 13: ...ource is not present on the input LED output power input source feed to the load Green LEDs on the line 1 the load is powered by input 1 Green LEDs on the line 2 the load is powered by input 2 FAULT L...

Page 14: ...following LEDs are illuminated Priority LED PS1 or PS2 depending on the default setting LED S1 LED S2 LED SW1 or SW2 according to the primary source First Switch on from Source 2 Check that all switch...

Page 15: ...djustable Working range voltage 80 145Vac 160 290Vac Nominal frequency 50 60 Hz auto sensing acceptance 15 Current 16 Amps OUTPUT Voltage range same as input Nominal frequency same as input Current 16...

Page 16: ...Items Specification Dimension W 430mm D 315mm H 44mm 1U Weight 5kg Packaging sizes W 585mm D 425mm H 184mm Structure Rack Mount Unit 1U Material Metallic Case Colour Pantone 432C Environment 7 5 Item...

Page 17: ...61000 2 2 LF Immunity IEC61000 4 6 level 2 Lab IEC61000 3 2 Harmonic Lab IEC61000 3 3 Flicks For ASYS 16A 230 only Overcurrent 7 8 Overload 105 to 125 20A 45 sec transfer is possible 126 to 150 24A 2...

Page 18: ...ed with the size of the unit in mind Disconnection devices must always be provided All protection devices circuit breakers and fuses installed upstream of the unit need to be co ordinated for discrimi...

Page 19: ...mains or feeding UPS units No mains voltage present Have mains inspected by qualified electrician Input fuses tripped Check and make sure the load ca pacity is within the specification then replace a...