SOARNEX EP100 Series Quick Installation Manual Download Page 9

EN

EN

EP100-05-31

EP100-08-62

LED Indicators

LED Indicator Color

Status

Description

 Power

Green  Green solid Power on
Off

 Light off

Power off

 Max
(Power Max)

Red

 Red

 solid

When the total PoE output 

power achieve Guard Band

 Red

 blinking

When PoE output power is 

over total budget

Off

 Light off

System still have spare 

power for new PD

 L/A
(Link/Act)

Amber

 Amber

 solid

When there is a secure 

connection (or link) to 

10/100Mbps Ethernet 

device at any of the ports

 Amber

 blinking

When there is reception or 

transmission of data 

occuring at 10/100 Mbps

The LEDs of the Switch are located on the front panel.

Summary of Contents for EP100 Series

Page 1: ...PoE PoE EP100 EP100 05 31 EP100 08 31 EP100 08 62 Rev 1 0 Aug 2017...

Page 2: ...1 EP100 x 1 2 48V DC 0 8A x 1 EP100 05 31 EP100 08 31 54V DC 1 67A x 1 EP100 08 62 3 x 1 4 x 4 5 1 82 6 http www soarnex com...

Page 3: ...LED EP100 08 31 LED Power Max Power Max PoE 7W PoE L A Link Act 10 100Mbps 10 100Mbps PoE Ports1 4 PoE PD PoE LED...

Page 4: ...EP100 05 31 EP100 08 62 LED Power Max Power Max PoE 7W PoE PoE L A Link Act 10 100Mbps 10 100Mbps 1000Mbps 1000Mbps PoE Ports1 4 PoE PD PoE LED LED...

Page 5: ...1 2 3 4 EP100 05 31 EP100 08 31 EP100 08 62...

Page 6: ...PoE PoE Unmanaged Switches EP100 Series EP100 05 31 EP100 08 31 EP100 08 62 Rev 1 0 Aug 2017 Quick Installation Guide...

Page 7: ...1 2A 50 60Hz DC output 54V 1 67A x1 for EP100 08 62 3 Rubber Footpads x 4 4 Quick Installation Guide Install the Switch in a suitable temperature humidity environment The power outlet should be within...

Page 8: ...still have spare power for new PD L A Link Act Amber Amber solid When there is a secure connection or link to 10 100Mbps Ethernet device at any of the ports Amber blinking When there is reception or t...

Page 9: ...r achieve Guard Band Red blinking When PoE output power is over total budget Off Light off System still have spare power for new PD L A Link Act Amber Amber solid When there is a secure connection or...

Page 10: ...sion of data occurring at 1000Mbps Off Light off No link PoE Ports1 4 Green Green solid Power feeding Green blinking Error condition Off Light off No power feeding Hardware Installation 1 Attach the r...

Page 11: ...EN Hardware Installation EP100 05 31 EP100 08 31 EP100 08 62...

Page 12: ...stalled and used in accordance with this user s guide may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference i...